Cervical Posterior Instrumentation Surgery Using a Patient-Specific Screw Guide Templating System: A Case Report.
Hirao, Yukino; Takahashi, Hiroshi; Koda, Masao; Funayama, Toru; Yamazaki, Masashi.
Affiliation
  • Hirao Y; Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, JPN.
  • Takahashi H; Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, JPN.
  • Koda M; Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, JPN.
  • Funayama T; Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, JPN.
  • Yamazaki M; Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, JPN.
Cureus ; 15(10): e47538, 2023 Oct.
Article in En | MEDLINE | ID: mdl-38022001
ABSTRACT
Posterior cervical pedicle screw (CPS) is one of the most robust forms of posterior instrumentation. Nonetheless, the spinal cord, nerve roots, and vertebral artery are situated in proximity to the cervical pedicle, engendering a significant risk of damage to these structures during CPS insertion. Here, we report a case of cervical posterior instrumentation surgery using a patient-specific three-dimensional (3D) screw guide templating system approved for the cervical spine (Myspine Cervical®). A 62-year-old man presented to our hospital with progressive numbness and paresthesia in both hands and fingers, as well as gait disturbance, which had persisted for one year. A neurological examination revealed severe myelopathy. Imaging findings showed severe spinal cord compression due to ossification of the posterior longitudinal ligament (OPLL) from C3/4 to C6/7. On the diagnosis of compression myelopathy due to cervical OPLL, we performed a posterior decompression and fusion surgery using a patient-specific 3D screw guide templating system (Myspine Cervical®). No severe complications occurred during the surgery. Evaluation of the CPS position by postoperative CT showed that all the CPS placements were accurate. The implementation of the patient-specific 3D screw guide templating system facilitated the secure and precise insertion of CPS in comparison to other surgical assist devices.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cureus Year: 2023 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cureus Year: 2023 Document type: Article