Your browser doesn't support javascript.
loading
Concerns on the Effects of Electrode Positions in Electrolyte Container for the Oxygen Evolution Reaction.
Zhang, Fan; Zhao, Yayun; Chen, Xiaofeng; Zhao, Shengxiao; Zhou, Junjie; Lu, Zhiyi; Lin, Yichao.
Affiliation
  • Zhang F; Renewable Energy Engineering Institute, Power China Huadong Engineering Corporation Limited, Hangzhou 311122, China.
  • Zhao Y; Key Laboratory of Far-Shore Wind Power Technology of Zhejiang Province, Hangzhou 311122, China.
  • Chen X; Key Laboratory of Advanced Fuel Cells and Electrolyzers Technology of Zhejiang Province, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China.
  • Zhao S; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Zhou J; Renewable Energy Engineering Institute, Power China Huadong Engineering Corporation Limited, Hangzhou 311122, China.
  • Lu Z; Key Laboratory of Far-Shore Wind Power Technology of Zhejiang Province, Hangzhou 311122, China.
  • Lin Y; Renewable Energy Engineering Institute, Power China Huadong Engineering Corporation Limited, Hangzhou 311122, China.
Molecules ; 28(24)2023 Dec 18.
Article in En | MEDLINE | ID: mdl-38138631
ABSTRACT
Water electrolysis is currently a major technique to produce clean hydrogen, which is regarded as a promising and sustainable energy carrier. The efficiency of water electrolysis is highly dependent on the oxygen evolution reaction (OER) on the anode. The evaluation of an OER electrocatalyst is frequently carried out on a three-electrode system in a container of electrolyte. Herein, we found that the electrode positions in the electrolyte container could significantly affect the data acquisition of OER performance. After a detailed investigation, we reveal that the difference of the OER activity of an electrocatalyst at a different position is originated from their different iRu drop and the gas diffusion resistance. For the first time, this work evokes concerns on the accurate evaluation of electrocatalysts regarding the electrode position. For fair comparisons and reliable results, it is strongly suggested to keep the electrode position unchanged in the electrochemical measurements. In addition, the establishment of a standard electrolyzer setup for electrocatalysis evaluation in the electrochemical community is also called for.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Molecules / Molecules (Basel) Journal subject: BIOLOGIA Year: 2023 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Molecules / Molecules (Basel) Journal subject: BIOLOGIA Year: 2023 Document type: Article Affiliation country: Country of publication: