Your browser doesn't support javascript.
loading
Removable versus fixed myo-functional appliances in class II malocclusion among Indians.
Pawar, Rahul; Nath, Shib Kumar; Kumar, P Kiran; Patel, Khyati; Arvind, Mengi; Shah, Alap; Dave, Bela; Mehta, Dhaval Niranjan.
Affiliation
  • Pawar R; Department of Orthodontic and Dentofacial Orthopaedics, JCD Dental College, Sirsa, Haryana, India.
  • Nath SK; Consultant Orthodontist, The Smile Architect Dental Clinic and Braces Centre, Agartala, Tripura, India.
  • Kumar PK; Department of Orthodontics and Dentofacial Orthopedics, College of Dental Sciences, Davangere, India.
  • Patel K; Department of Orthodontics and Dentofacial Orthopedics, Narsinhbhai Patel Dental College and Hospital, Sakalchand Patel University, Visnagar, Gujarat, India.
  • Arvind M; Department of Orthodontics, Indira Gandhi Government Dental College, Jammu, India.
  • Shah A; Department of Orthodontics and Dentofacial Orthopedics, Karnavati school of dentistry, Karnavati University, Uvarsad, Gandhinagar, India.
  • Dave B; Department of Periodontology, Ahmedabad Municipal Corporation Dental College, Ahmedabad, Gujarat, India.
  • Mehta DN; Department of Oral Medicine and Radiology, Narsinbhai Patel Dental college and Hospital, Sankalchand Patel University, Visnagar, Gujarat.
Bioinformation ; 19(13): 1318-1323, 2023.
Article in En | MEDLINE | ID: mdl-38415040
ABSTRACT
It is of interest to compare two myofunctional appliances (frankal appliance and twin bloc) and two fixed orthodontic appliances (PowerScope and Forsus) in management of class II div 1 malocclusion. A total of 56 Class II division 1 malocclusion patients indicated for treatment with myofunctional appliances and fixed functional appliances were randomized. They were equally divided among frankal appliance (n=14), twin block appliance (n=14), PowerScope (American Orthodontics) (n=14), Forsus (3M Unitek Corp) groups (n=14). Skeletal and dentoalveolar effects of all appliances were compared. SNB increased remarkably by 4.2° in the Twin block group and it was high among all treatment groups. There was a significant decrease in vertical dimensions (SN-GoGn) in the Twin block (p = 0.002). Early treatment of Class II due to mandibular retrusion with Twin block functional appliance is recommended due to its favorable skeletal effect.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Bioinformation Year: 2023 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Bioinformation Year: 2023 Document type: Article Affiliation country: Country of publication: