Your browser doesn't support javascript.
loading
An on-line SPE-LC-MS/MS method for quantification of nucleobases and nucleosides present in biological fluids.
Liu, Yi-Ming; Wang, Shuguan; Dickenson, Amani; Mao, Jinghe; Bai, Xiaolin; Liao, Xun.
Affiliation
  • Liu YM; Department of Chemistry, Physics, and Atmospheric Science, Jackson State University, Jackson, MS 39217, USA. yiming.liu@jsums.edu.
  • Wang S; Department of Chemistry, Physics, and Atmospheric Science, Jackson State University, Jackson, MS 39217, USA. yiming.liu@jsums.edu.
  • Dickenson A; Department of Chemistry, Physics, and Atmospheric Science, Jackson State University, Jackson, MS 39217, USA. yiming.liu@jsums.edu.
  • Mao J; Department of Biology, Tougaloo College, Tougaloo, MS 39174, USA.
  • Bai X; Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China. liaoxun@cib.ac.cn.
  • Liao X; Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China. liaoxun@cib.ac.cn.
Anal Methods ; 16(16): 2505-2512, 2024 04 25.
Article in En | MEDLINE | ID: mdl-38584507
ABSTRACT
Solid phase extraction (SPE) and liquid chromatographic (LC) separation of nucleobases and nucleosides are challenging due to the high hydrophilicity of these compounds. Herein we report a novel on-line SPE-LC-MS/MS method for their quantification after pre-column derivatization with chloroacetaldehyde (CAA). The method proposed is selective and sensitive with limits of detection at the nano-molar level. Analysis of urine and saliva samples by using this method is demonstrated. Adenine, guanine, cytosine, adenosine, guanosine, and cytidine were found in the range from 0.19 (guanosine) to 1.83 µM (cytidine) in urine and from 0.015 (guanosine) to 0.79 µM (adenine) in saliva. Interestingly, methylation of cytidine was found to be significantly different in urine from that in saliva. While 5-hydroxymethylcytidine was detected at a very low level (<0.05 µM) in saliva, it was found to be the most prominent methylated cytidine in urine at a high level of 3.33 µM. Since on-line SPE is deployed, the proposed LC-MS/MS quantitative assay is convenient to carry out and offers good assay accuracy and repeatability.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Saliva / Solid Phase Extraction / Nucleosides Limits: Humans Language: En Journal: Anal Methods Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Saliva / Solid Phase Extraction / Nucleosides Limits: Humans Language: En Journal: Anal Methods Year: 2024 Document type: Article Affiliation country: Country of publication: