Your browser doesn't support javascript.
loading
Microneedle System with Biomarker-Activatable Chromophore as Both Optical Imaging Probe and Anti-bacterial Agent for Combination Therapy of Bacterial-Infected Wounds and Outcome Monitoring.
Ouyang, Juan; Sun, Lihe; She, Zunpan; Li, Rong; Zeng, Fang; Yao, Zhicheng; Wu, Shuizhu.
Affiliation
  • Ouyang J; Biomedical Division, State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China.
  • Sun L; Biomedical Division, State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China.
  • She Z; Biomedical Division, State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China.
  • Li R; Biomedical Division, State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China.
  • Zeng F; Biomedical Division, State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China.
  • Yao Z; Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong 510630, China.
  • Wu S; Biomedical Division, State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China.
Article in En | MEDLINE | ID: mdl-38593207
ABSTRACT
Wounds infected with bacteria, if left untreated, have the potential to escalate into life-threatening conditions, such as sepsis, which is characterized by widespread inflammation and organ damage. A comprehensive approach to treating bacterial-infected wounds, encompassing the control of bacterial infection, biofilm eradication, and inflammation regulation, holds significant importance. Herein, a microneedle (MN) patch (FM@ST MN) has been developed, with silk fibroin (SF) and tannic acid-based hydrogel serving as the matrix. Encapsulated within the MNs are the AIEgen-based activatable probe (FQ-H2O2) and the NLRP3 inhibitor MCC950, serving as the optical reporter/antibacterial agent and the inflammation regulator, respectively. When applied onto bacterial-infected wounds, the MNs in FM@ST MN penetrate bacterial biofilms and gradually degrade, releasing FQ-H2O2 and MCC950. The released FQ-H2O2 responds to endogenously overexpressed reactive oxygen species (H2O2) at the wound site, generating a chromophore FQ-OH which emits noticeable NIR-II fluorescence and optoacoustic signals, enabling real-time imaging for outcome monitoring; and this chromophore also exhibits potent antibacterial capability due to its dual positive charges and shows negligible antibacterial resistance. However, the NLRP3 inhibitor MCC950, upon release, suppresses the activation of NLRP3 inflammasomes, thereby mitigating the inflammation triggered by bacterial infections and facilitating wound healing. Furthermore, SF in FM@ST MN aids in tissue repair and regeneration by promoting the proliferation of epidermal cells and fibroblasts and collagen synthesis. This MN system, free from antibiotics, holds promise as a solution for treating and monitoring bacterially infected wounds without the associated risk of antimicrobial resistance.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ACS Appl Mater Interfaces Journal subject: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Year: 2024 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ACS Appl Mater Interfaces Journal subject: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Year: 2024 Document type: Article Affiliation country: