Your browser doesn't support javascript.
loading
Diagnostic criteria of anterior segment swept-source optical coherence tomography to detect gonioscopic angle closure.
Guo, Philip Yawen; Zhang, Xiulan; Li, Fei; Lin, Chen; Nguyen, Anwell; Sakata, Rei; Higashita, Risa; Okamoto, Keiichiro; Yu, Marco; Aihara, Makoto; Aung, Tin; Lin, Shan; Leung, Christopher Kai-Shun.
Affiliation
  • Guo PY; Department of Ophthalmology, The University of Hong Kong, Pok Fu Lam, People's Republic of China.
  • Zhang X; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China.
  • Li F; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China.
  • Lin C; Shenzhen Aier Eye Hospital, Shenzhen, China.
  • Nguyen A; Department of Ophthalmology, University of California San Francisco, San Francisco, California, USA.
  • Sakata R; Ophthalmology, The University of Tokyo, Bunkyo-ku, Japan.
  • Higashita R; Tomey Corporation, Nagoya, Japan.
  • Okamoto K; Tomey Corporation, Nagoya, Japan.
  • Yu M; Singapore Eye Research Institute, Singapore.
  • Aihara M; Ophthalmology, Tokyo Daigaku Daigakuin Igakukei Kenkyuka Igakubu, Tokyo, Japan.
  • Aung T; Glaucoma, Singapore National Eye Centre, Singapore.
  • Lin S; Department of Ophthalmology, University of California San Francisco, San Francisco, California, USA.
  • Leung CK; Department of Ophthalmology, The University of Hong Kong, Pok Fu Lam, People's Republic of China cleung21@hku.hk.
Br J Ophthalmol ; 108(8): 1130-1136, 2024 Jul 23.
Article in En | MEDLINE | ID: mdl-38594062
ABSTRACT

AIMS:

To compare the diagnostic performance of 360° anterior segment optical coherence tomography assessment by applying normative percentile cut-offs versus iris trabecular contact (ITC) for detecting gonioscopic angle closure.

METHODS:

In this multicentre study, 394 healthy individuals were included in the normative dataset to derive the age-specific and angle location-specific normative percentiles of angle open distance (AOD500) and trabecular iris space area (TISA500) which were measured every 10° for 360°. 119 healthy participants and 170 patients with angle closure by gonioscopy were included in the test dataset to investigate the diagnostic performance of three sets of criteria for detection of gonioscopic angle closure (1) the 10th and (2) the 5th percentiles of AOD500/TISA500, and (3) ITC (ie, AOD500/TISA500=0 mm/mm2). The number of angle locations with angle closure defined by each set of the criteria for each eye was used to generate the receiver operating characteristic (ROC) curve for the discrimination between gonioscopic angle closure and open angle.

RESULTS:

Of the three sets of diagnostic criteria examined, the area under the ROC curve was greatest for the 10th percentile of AOD500 (0.933), whereas the ITC criterion AOD500=0 mm showed the smallest area under the ROC (0.852) and the difference was statistically significant with or without adjusting for age and axial length (p<0.001). The criterion ≥90° of AOD500 below the 10th percentile attained the best sensitivity 87.6% and specificity 84.9% combination for detecting gonioscopic angle closure.

CONCLUSIONS:

Applying the normative percentiles of angle measurements yielded a higher diagnostic performance than ITC for detecting angle closure on gonioscopy.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Glaucoma, Angle-Closure / ROC Curve / Tomography, Optical Coherence / Gonioscopy / Intraocular Pressure / Anterior Eye Segment Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Br J Ophthalmol Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Glaucoma, Angle-Closure / ROC Curve / Tomography, Optical Coherence / Gonioscopy / Intraocular Pressure / Anterior Eye Segment Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Br J Ophthalmol Year: 2024 Document type: Article