Your browser doesn't support javascript.
loading
High-Frequency and High-Current Transmission Techniques for Multiple Earth Electrical Characteristic Measurement Systems Based on Adaptive Impedance Matching through Phase Comparison.
Zhang, Kuiyuan; Yang, Shulin; Wang, Meng; Zhang, Rongbo.
Affiliation
  • Zhang K; School of Geophysics and Information Technology, China University of Geosciences Beijing, Beijing 100083, China.
  • Yang S; Key Laboratory of Intraplate Volcanoes and Earthquakes, China University of Geosciences, Beijing 100083, China.
  • Wang M; School of Geophysics and Information Technology, China University of Geosciences Beijing, Beijing 100083, China.
  • Zhang R; School of Geophysics and Information Technology, China University of Geosciences Beijing, Beijing 100083, China.
Sensors (Basel) ; 24(10)2024 May 14.
Article in En | MEDLINE | ID: mdl-38793961
ABSTRACT
With the increase in groundwater exploration, underground mineral resource exploration, and non-destructive investigation of cultural relics, high-resolution earth electrical characteristic measurement has emerged as a mainstream technique owing to its advantageous non-destructive detection capability. To enhance the transmission power of the high-frequency transmitter in high-resolution multiple earth electrical characteristic measurement systems (MECS), this study proposes a high-frequency, high-current transmission technique based on adaptive impedance matching and implemented through the integration of resonant capacitors, a controllable reactor, high-frequency transformers, and corresponding control circuits. A high-current precisely controllable reactor with a 94% inductance variation range was designed and combined with resonant capacitors to reduce circuit impedance. Additionally, high-frequency transformers were employed to further increase the transmission voltage. A prototype was developed and tested, demonstrating an increase in transmission current at frequencies between 10 and 120 kHz with a peak active power of 200 W. Under the same transmission voltage, compared to the transmission circuit without impedance matching, the transmission current increased to a maximum of 16.7 times (average of 10.8 times), whereas compared to the transmission circuit using only traditional impedance matching, the transmission current increased by a maximum of 10.0 times (average of 4.2 times), effectively improving the exploration resolution.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Affiliation country: Country of publication: