Your browser doesn't support javascript.
loading
In-vivo blood pressure sensing with bi-filler nanocomposite.
Kushwah, Chandrabhan; Riesenhuber, Martin; Asmul, Søren; Gyöngyösi, Mariann; Nogaret, Alain.
Affiliation
  • Kushwah C; Department of Physics, University of Bath, Bath BA2 7AY, United Kingdom.
  • Riesenhuber M; Department of Medicine, University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.
  • Asmul S; Medtronic Bakken Research Centre, Endepolsdomein 5, the Netherlands.
  • Gyöngyösi M; Department of Medicine, University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.
  • Nogaret A; Department of Physics, University of Bath, Bath BA2 7AY, United Kingdom. Electronic address: A.R.Nogaret@bath.ac.uk.
Biomater Adv ; 162: 213905, 2024 Sep.
Article in En | MEDLINE | ID: mdl-38815550
ABSTRACT
Conductive elastomers present desirable qualities for sensing pressure in-vivo, such as high piezoresistance in tiny volumes, conformability and, biocompatibility. Many electrically conductive nanocomposites however, are susceptible to electrical drift following repeated stress cycles and chemical aging. Here we propose an innovative approach to stabilize nanocomposite percolation network against incomplete recovery to improve reproducibility and facilitate sensor calibration. We decouple the tunnelling-percolation network of highly-oriented pyrolytic graphite (HOPG) nanoparticles from the incomplete viscoelastic recovery of the polydimethylsiloxane (PDMS) matrix by inserting minute amounts of insulating SiO2 nanospheres. SiO2 nanospheres effectively reduce the number of nearest neighbours at each percolation node switching off the parallel electrical pathways that might become activated under incomplete viscoelastic relaxation. We varied the size of SiO2 nanospheres and their filling fraction to demonstrate nearly complete piezoresistance recovery when SiO2 and HOPG nanoparticles have equal diameters (≈400 nm) and SiO2 and HOPG volume fractions are 1 % and 29.5 % respectively. We demonstrate an in-vivo blood pressure sensor based on this bi-filler composite.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Silicon Dioxide / Nanocomposites / Graphite Limits: Humans Language: En Journal: Biomater Adv Year: 2024 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Silicon Dioxide / Nanocomposites / Graphite Limits: Humans Language: En Journal: Biomater Adv Year: 2024 Document type: Article Affiliation country:
...