Your browser doesn't support javascript.
loading
Nanomolar level electrochemical detection of glycine on a miniaturized modified screen-printed carbon-based electrode: a comparison of performance with glassy carbon electrode system.
S, Saisree; Shamili, Chandradas; K Y, Sandhya; Peethambharan, Surendran Kuzhichalil; Chandran, Achu.
Affiliation
  • S S; Materials Science and Technology Division, CSIR-National Institute of Interdisciplinary Science and Technology, Industrial Estate, Thiruvananthapuram-695 019, Kerala, India. saisreesn@gmail.com.
  • Shamili C; Materials Science and Technology Division, CSIR-National Institute of Interdisciplinary Science and Technology, Industrial Estate, Thiruvananthapuram-695 019, Kerala, India. saisreesn@gmail.com.
  • K Y S; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad- 201002, India.
  • Peethambharan SK; Department of Chemistry, Indian Institute of Space Science and Technology Valiyamala, Thiruvananthapuram 695547, Kerala, India.
  • Chandran A; Materials Science and Technology Division, CSIR-National Institute of Interdisciplinary Science and Technology, Industrial Estate, Thiruvananthapuram-695 019, Kerala, India. saisreesn@gmail.com.
J Mater Chem B ; 12(31): 7557-7563, 2024 Aug 07.
Article in En | MEDLINE | ID: mdl-38979673
ABSTRACT
In this work, we demonstrate the electrochemical (EC) sensing of glycine (GLY) on a gold-copper nanocluster on nitrogen-doped graphene quantum dot-modified (indigenously fabricated) screen-printed electrode (AuCuNC@N-GQD/SPE). SPE was fabricated by step-by-step printing of reference, working, and counter electrodes to develop an all-printed SPE. A comparison strategy between SPE and the glassy carbon electrode (GCE) towards the EC sensing of GLY was carried out. The sensing performance was enhanced while replacing GCE with SPE. The limit of detection (LOD) for GLY obtained by EC sensing with AuCuNC@N-GQD/GCE was 10 nM and that with AuCuNC@N-GQD/SPE was 10 times lower, 1 nM, and is the lowest LOD value reported hitherto. Compared with AuCuNC@N-GQD/GCE, the current response of AuCuNC@N-GQD/SPE exhibited a ∼2.6-times enhancement with a sensitivity of 0.206 µA µM-1 cm-2. Thus, the successful shift from GCE to SPE not only miniaturizes the sensor device but also enhances the electrochemical detection performance.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Carbon / Electrodes / Electrochemical Techniques / Glycine Language: En Journal: J Mater Chem B Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Carbon / Electrodes / Electrochemical Techniques / Glycine Language: En Journal: J Mater Chem B Year: 2024 Document type: Article Affiliation country: Country of publication: