Establishment of a swine model of delayed bleeding after endoscopic procedure.
Uehara, Shohei; Sasaki, Fumisato; Sahara, Hisashi; Tanaka, Akihito; Hinokuchi, Makoto; Maeda, Hidehito; Arima, Shiho; Hashimoto, Shinichi; Kanmura, Shuji; Ido, Akio.
Affiliation
  • Uehara S; Digestive and Lifestyle Diseases Kagoshima University Graduate School of Medical and Dental Sciences Kagoshima Japan.
  • Sasaki F; Digestive and Lifestyle Diseases Kagoshima University Graduate School of Medical and Dental Sciences Kagoshima Japan.
  • Sahara H; Division of Experimental Large Animal Research Life Science and Laboratory Animal Research Unit Center for Advanced Science Research and Promotion Kagoshima University Kagoshima Japan.
  • Tanaka A; Digestive and Lifestyle Diseases Kagoshima University Graduate School of Medical and Dental Sciences Kagoshima Japan.
  • Hinokuchi M; Digestive and Lifestyle Diseases Kagoshima University Graduate School of Medical and Dental Sciences Kagoshima Japan.
  • Maeda H; Digestive and Lifestyle Diseases Kagoshima University Graduate School of Medical and Dental Sciences Kagoshima Japan.
  • Arima S; Digestive and Lifestyle Diseases Kagoshima University Graduate School of Medical and Dental Sciences Kagoshima Japan.
  • Hashimoto S; Digestive and Lifestyle Diseases Kagoshima University Graduate School of Medical and Dental Sciences Kagoshima Japan.
  • Kanmura S; Digestive and Lifestyle Diseases Kagoshima University Graduate School of Medical and Dental Sciences Kagoshima Japan.
  • Ido A; Digestive and Lifestyle Diseases Kagoshima University Graduate School of Medical and Dental Sciences Kagoshima Japan.
Article in En | MEDLINE | ID: mdl-39050142
ABSTRACT

Objectives:

Although delayed bleeding after endoscopic procedures has become a problem, currently, there are no appropriate animal models to validate methods for preventing it. This study aimed to establish an animal model of delayed bleeding after endoscopic procedures of the gastrointestinal tract.

Methods:

Activated coagulation time (ACT) was measured using blood samples drawn from a catheter inserted into the external jugular vein of swine (n = 7; age, 6 months; mean weight, 13.8 kg) under general anesthesia using the cut-down method. An upper gastrointestinal endoscope was inserted orally, and 12 mucosal defects were created in the stomach by endoscopic mucosal resection using a ligating device. Hemostasis was confirmed at this time point. The heparin group (n = 4) received 50 units/kg of unfractionated heparin via a catheter; after confirming that the ACT was ≥200 s 10 min later, continuous heparin administration (50 units/kg/h) was started. After 24 h, an endoscope was inserted under general anesthesia to evaluate the blood volume in the stomach and the degree of blood adherence at the site of the mucosal defect.

Results:

Delayed bleeding was observed in three swine (75%) in the heparin-treated group, who had a maximum ACT of >220 s before the start of continuous heparin administration. In the non-treated group (n = 3), no prolonged ACT or delayed bleeding was observed at 24 h.

Conclusion:

An animal model of delayed bleeding after an endoscopic procedure in the gastrointestinal tract was established using a single dose of heparin and continuous heparin administration after confirming an ACT of 220 s.