Your browser doesn't support javascript.
loading
Skin-attachable Tb-MOF ratio fluorescent sensor for real-time detection of human sweat pH.
Chen, Qiulin; Li, Sheng; Tu, Xiaoyan; Zhang, Xinfeng.
Affiliation
  • Chen Q; College of Materials and Chemistry & Chemical Engineering, Chengdu University of Technology, Chengdu, 610059, China.
  • Li S; College of Materials and Chemistry & Chemical Engineering, Chengdu University of Technology, Chengdu, 610059, China.
  • Tu X; College of Materials and Chemistry & Chemical Engineering, Chengdu University of Technology, Chengdu, 610059, China.
  • Zhang X; College of Materials and Chemistry & Chemical Engineering, Chengdu University of Technology, Chengdu, 610059, China. Electronic address: zhangxinfeng09@cdut.cn.
Biosens Bioelectron ; 263: 116606, 2024 Jul 25.
Article in En | MEDLINE | ID: mdl-39089190
ABSTRACT
The pH of human sweat is highly related with a variety of diseases, whereas the monitoring of sweat pH still remains challenging for ordinary families. In this study, we developed a novel dual-emission Tb-MOF using DPA as the ligand and further designed and constructed a skin-attachable Tb-MOF ratio fluorescent sensor for real-time detection of human sweat pH. With the increased concentration of H+, the interaction of H+ with carbonyl organic ligand leads to the collapse of the Tb-MOF crystal structure, resulting in the interruption of antenna effect, and correspondingly increasing the emission of the ligand at 380 nm and decreasing the emission of the central ion Tb3+ at 544 nm. This Tb-MOF nanoprobe has a good linear response in the pH range of 4.12-7.05 (R2 = 0.9914) with excellent anti-interference ability. Based on the merits of fast pH response and high sensitivity, the nanoprobe was further used to prepare flexible wearable sensor. The wearable sensor can detect pH in the linear range of 3.50-6.70, which covers the pH range of normal human sweat (4.50-6.50). Subsequently, the storage stability and detection accuracy of the sensors were evaluated. Finally, the sensor has been successfully applied for the detection of pH in actual sweat samples from 21 volunteer and the real-time monitoring of pH variation during movement processing. This skin-attachable Tb-MOF sensor, with the advantages of low cost, visible color change and long shelf-life, is appealing for sweat pH monitoring especially for ordinary families.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Biosens Bioelectron Journal subject: BIOTECNOLOGIA Year: 2024 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Biosens Bioelectron Journal subject: BIOTECNOLOGIA Year: 2024 Document type: Article Affiliation country: