Your browser doesn't support javascript.
loading
Disposable Zirconium trisulfide-Reduced graphene oxide modified conducting thread based electrochemical biosensor for lung cancer diagnosis.
Shankar, Saurav; Kumar, Yogesh; Sharma, Neera; Chandra, Ramesh; Kumar, Suveen.
Affiliation
  • Shankar S; Department of Chemistry, University of Delhi, Delhi 110007, India.
  • Kumar Y; Department of Chemistry, University of Delhi, Delhi 110007, India.
  • Sharma N; Department of Chemistry, Hindu College, University of Delhi, Delhi 110007, India.
  • Chandra R; Department of Chemistry, University of Delhi, Delhi 110007, India; Maharaja Surajmal Brij University, Kumher, Bharatpur 321201, India. Electronic address: acbrdu@hotmail.com.
  • Kumar S; Department of Chemistry, University of Delhi, Delhi 110007, India. Electronic address: suveeendev@gmail.com.
Bioelectrochemistry ; 160: 108801, 2024 Aug 23.
Article in En | MEDLINE | ID: mdl-39226732
ABSTRACT
Flexible technology in sensors have received much attention in monitoring of human health through various physiological indicators. Thus, it drawn a lot of interest in the development of flexible substrate for the diagnosis of various diseases via analysis of analytes. Present work focusses on the development of ecofriendly, portable, flexible, conducting thread (Th) and used as smart substrate for fabrication of biosensor towards ultrasensitive detection of the lung cancer biomarker (cytoskeleton-associated protein 4; CKAP4). The zirconium trisulfide-reduced graphene oxide nanocomposite and poly(3,4-ethylenedioxythiophene)poly(styrenesulfonate) (PEDOTPSS) modified cotton thread based biosensor was fabricated via dip coating method. Next, successive immobilization of monoclonal antibodies of CKAP4 (anti-CKAP4) and bovine serum albumin (BSA) was performed via drop cast approach using fabricated electrode [nZrS3@rGO/PEDOTPSS/Th]. The response of fabricated electrode (BSA/anti-CKAP4/ZrS3@rGO/PEDOTPSS/Th) was recorded electrochemically versus CKAP4 concentration via chronoamperometry (CA). The results showed wider linear detection range of 6.25-800 pg mL-1, excellent sensitivity of 85.2 µA[log(pg mL-1)]-1cm-2 with good stability up to 42 days. The response of fabricated biosensor was supported by investigating response of CKAP4 biomarker present in patients of lung cancer (concentration as determined through enzyme-linked immunosorbent assay) and obtained results exhibited excellent correlation with that of standard samples.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Bioelectrochemistry Journal subject: BIOQUIMICA Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Bioelectrochemistry Journal subject: BIOQUIMICA Year: 2024 Document type: Article Affiliation country: Country of publication: