Your browser doesn't support javascript.
loading
Comparison of measurements and calculated lens power using three biometers: a Scheimpflug tomographer with partial coherence interferometry and two swept source optical coherence tomographers.
Ang, Robert Edward T; Estolano, Benedict L; Luz, Paulo Hector C; Umali, Maria Isabel N; Araneta, Michelle Marie Q; Cruz, Emerson M.
Affiliation
  • Ang RET; Asian Eye Institute, 8th Floor PHINMA Plaza Bldg., Hidalgo Drive, Rockwell Center, Makati City, 1200, Philippines. rtang@asianeyeinstitute.com.
  • Estolano BL; Cardinal Santos Medical Center, 10 Wilson St., Greenhills West, San Juan City, 1502, Philippines. rtang@asianeyeinstitute.com.
  • Luz PHC; Cardinal Santos Medical Center, 10 Wilson St., Greenhills West, San Juan City, 1502, Philippines.
  • Umali MIN; Asian Eye Institute, 8th Floor PHINMA Plaza Bldg., Hidalgo Drive, Rockwell Center, Makati City, 1200, Philippines.
  • Araneta MMQ; Asian Eye Institute, 8th Floor PHINMA Plaza Bldg., Hidalgo Drive, Rockwell Center, Makati City, 1200, Philippines.
  • Cruz EM; Asian Eye Institute, 8th Floor PHINMA Plaza Bldg., Hidalgo Drive, Rockwell Center, Makati City, 1200, Philippines.
BMC Ophthalmol ; 24(1): 410, 2024 Sep 19.
Article in En | MEDLINE | ID: mdl-39300358
ABSTRACT

PURPOSE:

To compare the biometric measurements obtained from the Pentacam AXL Wave, IOLMaster 700, and ANTERION and calculate the recommended intraocular lens power using the Barrett Formulae.

METHODS:

This was a retrospective cross-sectional study of patients who underwent biometry using the Pentacam AXL Wave, IOLMaster 700, and ANTERION. Flat keratometry (K1), steep keratometry (K2), anterior chamber depth (ACD), and axial length (AL) from each device were measured and compared. These parameters were used to calculate the recommended IOL powers using the Barrett formula.

RESULTS:

The study included 252 eyes of 153 patients. The IOLMaster had the highest acquisition rate among the two biometers. The Pentacam obtained the shortest mean AL, the IOLMaster measured the highest mean keratometry values, and the ANTERION measured the highest mean ACD. In terms of pairwise comparisons, keratometry and axial length were not significantly different between the Pentacam-IOLMaster and ANTERION-IOLMaster groups, while the rest of the pairwise comparisons were statistically significant. In nontoric and toric eyes, 35-45% of patients recommended the same sphere of IOL power. In another 30-40%, the Pentacam and ANTERION recommended an IOL power one step greater than that of the IOLMaster-derived data. 50% of the study population recommended the same toric-cylinder IOL power.

CONCLUSIONS:

The Pentacam AXL Wave, IOLMaster 700, and ANTERION can reliably provide data for IOL power calculations; however, these data are not interchangeable. In nontoric and toric eyes, 35-45% of cases recommended the same sphere IOL power, and in another 30-40%, the Pentacam and ANTERION recommended one-step higher IOL power than the IOLMaster-derived data. In targeting emmetropia, selecting the first plus IOL power is advisable when using the Pentacam and ANTERION to approximate the IOL power calculations recommended by the IOLMaster 700.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biometry / Tomography, Optical Coherence / Interferometry / Lenses, Intraocular Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: BMC Ophthalmol Journal subject: OFTALMOLOGIA Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biometry / Tomography, Optical Coherence / Interferometry / Lenses, Intraocular Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: BMC Ophthalmol Journal subject: OFTALMOLOGIA Year: 2024 Document type: Article Affiliation country: Country of publication: