Your browser doesn't support javascript.
loading
Pletismografía corporal (I): estandarización y criterios de calidad / Body plethysmography (I): Standardisation and quality criteria
Mir Messa, I de; Sardón Prado, O; Larramona, H; Salcedo Posadas, A; Villa, JR.
Affiliation
  • Mir Messa, I de; Hospital Universitario Vall d'Hebron. Sección de Neumología Pediátrica y Fibrosis Quística. Barcelona. España
  • Sardón Prado, O; Hospital Universitario Donostia. Sección de Neumología Pediátrica. España
  • Larramona, H; Consorci Hospittalari Parc Taulí. Sección de Neumología Pediátrica. Barcelona. España
  • Salcedo Posadas, A; Hospital Maternoinfantil Gregorio Marañón. Sección de Neumología. Madrid. España
  • Villa, JR; Hospital Infantil Universitario Niño Jesús. Sección de Neumología. Madrid. España
An. pediatr. (2003. Ed. impr.) ; 83(2): 136.e1-136.e7, ago. 2015. tab, ilus
Article in Es | IBECS | ID: ibc-139406
Responsible library: ES1.1
Localization: BNCS
RESUMEN
La pletismografía corporal completa permite la medición de volúmenes, capacidades y resistencias pulmonares. Es una técnica bien estandarizada y ampliamente utilizada en neumología pediátrica, aunque requiere equipo específico, personal especializado y cierta colaboración por parte del paciente. La pletismografía utiliza la ley de Boyle para determinar el volumen de gas intratorácico o capacidad residual funcional, y una vez determinada esta, se extrapolan el volumen residual y la capacidad pulmonar total. La medición de la capacidad pulmonar total es necesaria para el diagnóstico de patología restrictiva. La resistencia de la vía aérea es una medida de obstrucción, pudiéndose determinar la resistencia total, que incluye la resistencia de la pared torácica, tejido pulmonar y vía aérea, y la resistencia específica, que es un parámetro más estable que corresponde al producto de la resistencia de la vía aérea por la capacidad residual funcional. La complejidad de esta técnica, las ecuaciones de referencia, las diferencias en el equipamiento, la variabilidad de la misma y las condiciones en las que se realiza han hecho necesaria su estandarización. Se analizan a lo largo del artículo los aspectos prácticos de esta técnica, especificando las recomendaciones para su realización, sistemática de calibración y los cálculos que se deben llevar a cabo, así como la interpretación de los resultados obtenidos. El objetivo de esta publicación es favorecer una mejor comprensión de los principios de la pletismografía completa con el fin de optimizar la interpretación de los resultados favoreciendo un mejor manejo del paciente y un consenso en la especialidad (AU)
ABSTRACT
Whole body plethysmography is used to measure lung volumes, capacities and resistances. It is a well standardised technique, and although it is widely used in paediatric chest diseases units, it requires specific equipment, specialist staff, and some cooperation by the patient. Plethysmography uses Boyle's law in order to measure the intrathoracic gas volume or functional residual capacity, and once this is determined, the residual volume and total lung capacity is extrapolated. The measurement of total lung capacity is necessary for the diagnosis of restrictive diseases. Airway resistance is a measurement of obstruction, with the total resistance being able to be measured, which includes chest wall, lung tissue and airway resistance, as well as the specific airway resistance, which is a more stable parameter that is determined by multiplying the measured values of airway resistance and functional residual capacity. The complexity of this technique, the reference equations, the differences in the equipment and their variability, and the conditions in which it is performed, has led to the need for its standardisation. Throughout this article, the practical aspects of plethysmography are analysed, specifying recommendations for performing it, its systematic calibration and the calculations that must be made, as well as the interpretation of the results obtained. The aim of this article is to provide a better understanding of the principles of whole body plethysmography with the aim of optimising the interpretation of the results, leading to improved management of the patient, as well as a consensus among the speciality (AU)
Subject(s)

Full text: 1 Collection: 06-national / ES Database: IBECS Main subject: Plethysmography, Whole Body / Residual Volume / Functional Residual Capacity Type of study: Diagnostic_studies / Guideline Limits: Child / Female / Humans / Male Language: Es Journal: An. pediatr. (2003. Ed. impr.) Year: 2015 Document type: Article

Full text: 1 Collection: 06-national / ES Database: IBECS Main subject: Plethysmography, Whole Body / Residual Volume / Functional Residual Capacity Type of study: Diagnostic_studies / Guideline Limits: Child / Female / Humans / Male Language: Es Journal: An. pediatr. (2003. Ed. impr.) Year: 2015 Document type: Article