PCR detects HCV RNA in a plasma pool contaminated by a single preseroconversion donation of genotype 5a.
Vox Sang
; 79(2): 69-71, 2000.
Article
in En
| MEDLINE
| ID: mdl-11054042
BACKGROUND AND OBJECTIVES: To determine the prevalence of HCV-RNA-positive plasma pools in Belgium, to validate our PCR method and to increase the safety of the released blood products. MATERIALS AND METHODS: Plasma pools consisting each of about 5,000 donations from Belgian unpaid volunteer blood donors were analysed by PCR for the presence of HCV RNA. Two different extraction methods were compared and validated. RESULTS: Two out of 367 plasma pools were found to be HCV RNA positive and were discarded. For one of these two pools, the look-back procedure identified an anti-HCV-negative contaminated donation. The HCV genotype of both the contaminated pool and the donation was 5a, a genotype rare in Europe. The viral load of the preseroconverted donation was 2.9 x 10(7) gEq/ml according to the bDNA method. CONCLUSION: In the case of plasma derivatives, various important steps are already included to increase safety. Nucleic acid testing of manufacturing plasma pools ensures that viral load in the starting material is as low as possible.
Search on Google
Collection:
01-internacional
Database:
MEDLINE
Main subject:
RNA, Viral
/
Polymerase Chain Reaction
/
Hepatitis C
/
Hepacivirus
Type of study:
Diagnostic_studies
/
Prevalence_studies
/
Prognostic_studies
/
Risk_factors_studies
Limits:
Humans
Country/Region as subject:
Europa
Language:
En
Journal:
Vox Sang
Year:
2000
Document type:
Article
Affiliation country:
Bélgica
Country of publication:
Reino Unido