[Evaluation of spinal cord ischemia in endovascular stent graft repair and surgical operation of descending thoracic or thoracoabdominal aortic aneurysms].
Koizumi, N; Obitsu, Y; Koide, K; Sato, K; Saiki, N; Watanabe, Y; Ichihashi, H; Yokoi, Y; Shimazaki, T; Kawaguchi, S; Ishimaru, S.
Affiliation
  • Koizumi N; Second Department of Surgery, Tokyo Medical University, Tokyo, Japan.
Kyobu Geka ; 57(4): 262-7, 2004 Apr.
Article in Ja | MEDLINE | ID: mdl-15071857
ABSTRACT
Between October 1996 and June 2003, endovascular stent graft repair was performed in 87 patients with descending thoracic aortic aneurysms, graft replacement was performed in 24 patients with thoracoabdominal aortic aneurysms, and endovascular stent graft repair with concomitant surgical bypass of abdominal visceral arteries was performed in 3 patients with thoracoabdominal aortic aneurysms. The retrievable stent graft was inserted and evoked spinal cord potential were monitored in order to predict spinal cord ischemia for stent graft repair. There was no paraplegia or hospital death, although 3 patients had paraparesis in stent graft repair. Two of the 3 patients with paraparesis made a full neurologic recovery. There were no cases of paraplegia or paraparesis in surgical operations with thoracoabdominal aortic aneurysm. The concomitant surgical procedure was a good technique for patients in whom cardiopulmonary bypass could not be used. Our results of stent graft repair and surgical operation for descending thoracic or thoracoabdominal aortic aneurysms were acceptable. The retrievable stent graft was useful for prediction of spinal cord ischemia before endovascular stent graft repair of descending thoracic or thoracoabdominal aortic aneurysm.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Spinal Cord / Stents / Monitoring, Intraoperative / Aortic Aneurysm, Thoracic / Aortic Aneurysm, Abdominal / Spinal Cord Ischemia / Evoked Potentials / Intraoperative Complications Type of study: Prognostic_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: Ja Journal: Kyobu Geka Year: 2004 Document type: Article Affiliation country: Japón Publication country: JAPAN / JAPON / JAPÃO / JP
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Spinal Cord / Stents / Monitoring, Intraoperative / Aortic Aneurysm, Thoracic / Aortic Aneurysm, Abdominal / Spinal Cord Ischemia / Evoked Potentials / Intraoperative Complications Type of study: Prognostic_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: Ja Journal: Kyobu Geka Year: 2004 Document type: Article Affiliation country: Japón Publication country: JAPAN / JAPON / JAPÃO / JP