Energy-selective neutron radiography and tomography at FRM.
Kardjilov, Nikolay; Schillinger, Burkhard; Steichele, Erich.
Affiliation
  • Kardjilov N; Physik Department, Fakultät für Physik E21, Technische Universität München, Garching D-85747, Germany. kardjilov@hmi.de
Appl Radiat Isot ; 61(4): 455-60, 2004 Oct.
Article in En | MEDLINE | ID: mdl-15246383
ABSTRACT
At the reactor FRM at Technical University of Munich energy-selective neutron radiography and tomography experiments were performed. For an energy separation of the neutrons from the primary beam a mechanical velocity selector was used. The radiography images show a different contrast of the investigated elements for neutron energies below and above their Bragg-cutoff energy. A comparison between the standard and energy-selective neutron tomography is presented. In spite of a reduction of the neutron intensity due to the velocity selector technique a realistic experimental time in order of some hours for the tomography experiment was achieved.
Search on Google
Collection: 01-internacional Database: MEDLINE Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2004 Document type: Article Affiliation country: Alemania