Your browser doesn't support javascript.
loading
Metabolic gas kinetics depend upon the level of exercise performed.
Witte, Klaus K A; Thackray, Simon D R; Lindsay, Kenneth A; Cleland, John G F; Clark, Andrew L.
Affiliation
  • Witte KK; Department of Academic Cardiology, Castle Hill Hospital, Castle Road, Cottingham, Hull HU16 5JQ, United Kingdom. klauswitte@hotmail.com
Eur J Heart Fail ; 7(6): 991-6, 2005 Oct.
Article in En | MEDLINE | ID: mdl-16115799
ABSTRACT

BACKGROUND:

The kinetics of oxygen and carbon dioxide at the onset of and recovery from exercise are slowed in patients with chronic heart failure (CHF). The aim of the present study was to establish whether the kinetics of O2 are influenced by the work rate.

METHODS:

Thirteen CHF patients and 12 control subjects underwent bicycle-based peak exercise testing with metabolic gas exchange analysis. Each subject then exercised at 15%, 25% and 50% of the maximal workload achieved until reaching steady state. Time constants for onset (T(onset)) and offset (T(offset)) for O2 uptake and CO2 output were correlated to the workload and the percentage of peak V(O2) performed during the steady state tests.

RESULTS:

Patients had lower peak oxygen uptake (pV(O2)) and the relation between ventilation and carbon dioxide output was steeper in patients than controls. T(offset) for both oxygen (O2) and carbon dioxide (CO(2)) from peak exercise was significantly greater in the patients than the controls and correlated with peak V(O2) (r=0.56, p<0.005 and r=0.58, p<0.005). T(onset) and T(offset) for O2 were increased in patients for each of the steady state tests and peak V(O2) correlated with T for recovery of O2 (r=0.44; p<0.05 from 15%, r=0.35; p= or <0.05 from 25%, and r=0.54; p<0.01 from 50%). There was a correlation between the T(onset) (r=0.42; p<0.0005 for O2 and r=0.23; p<0.05 for CO2) and T(offset) (r=0.49; p<0.0001 for O2 and r=0.42; p<0.0005 for CO2) and oxygen uptake as a percentage of peak exercise.

CONCLUSIONS:

This study demonstrates that the time constants of onset and offset for oxygen are dependent upon the degree of exertion performed relative to the individual's peak capacity.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Oxygen / Carbon Monoxide / Exercise Tolerance / Exercise Test / Heart Failure Type of study: Etiology_studies / Observational_studies / Risk_factors_studies Limits: Female / Humans / Male / Middle aged Language: En Journal: Eur J Heart Fail Journal subject: CARDIOLOGIA Year: 2005 Document type: Article Affiliation country: Reino Unido Publication country: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Oxygen / Carbon Monoxide / Exercise Tolerance / Exercise Test / Heart Failure Type of study: Etiology_studies / Observational_studies / Risk_factors_studies Limits: Female / Humans / Male / Middle aged Language: En Journal: Eur J Heart Fail Journal subject: CARDIOLOGIA Year: 2005 Document type: Article Affiliation country: Reino Unido Publication country: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM