Voltammetric studies on the antibiotic drug cefoperazone quantification and pharmacokinetic studies.
J Pharm Biomed Anal
; 42(4): 523-7, 2006 Oct 11.
Article
in En
| MEDLINE
| ID: mdl-16782297
ABSTRACT
A fully validated simple, sensitive and selective square-wave stripping voltammetry procedure was described for the trace quantification of cefoperazone in bulk form, formulations and human serum/plasma. The procedure was based on reduction of the adsorbed drug onto a hanging mercury drop electrode. The procedural conditions were optimized as frequency=60Hz, scan increment=8mV, pulse amplitude=25mV, preconcentration potential=-0.3V (versus Ag/Ag/KCl(s)), preconcentration duration=60-150s and an acetate buffer of pH 4.2 as a supporting electrolyte. A limit of detection of 4.5x10(-10)M and a limit of quantitation of 1.5x10(-9)M bulk cefoperazone were achieved following preconcentration of the drug onto the hanging mercury drop electrode for 150s. The proposed square-wave adsorptive cathodic stripping voltammetric procedure was successfully applied for trace quantification of cefoperazone in human serum and plasma. The achieved limits of detection and quantitation of the drug in human serum were 6x10(-10)M (0.375ngml(-1)) and 2x10(-9)M (1.250ngml(-1)), respectively. The pharmacokinetic parameters of cefoperazone in plasma of hospitalized volunteers were successfully estimated.
Search on Google
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Cefoperazone
/
Electrochemistry
/
Anti-Bacterial Agents
Limits:
Humans
/
Male
Language:
En
Journal:
J Pharm Biomed Anal
Year:
2006
Document type:
Article
Affiliation country:
Egipto