Impact of autoclave sterilization on the activity and structure of formulated heparin.
Beaudet, Julie M; Weyers, Amanda; Solakyildirim, Kemal; Yang, Bo; Takieddin, Majde; Mousa, Shaker; Zhang, Fuming; Linhardt, Robert J.
Affiliation
  • Beaudet JM; Department of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180.
  • Weyers A; Department of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180.
  • Solakyildirim K; Department of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180.
  • Yang B; Department of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180.
  • Takieddin M; The Pharmaceutical Research Institute, Albany College of Pharmacy and Health Sciences, Albany, New York 12208.
  • Mousa S; The Pharmaceutical Research Institute, Albany College of Pharmacy and Health Sciences, Albany, New York 12208.
  • Zhang F; Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180. Electronic address: zhangf2@rpi.edu.
  • Linhardt RJ; Department of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180; Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180; Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studie
J Pharm Sci ; 100(8): 3396-3404, 2011 Aug.
Article in En | MEDLINE | ID: mdl-21416466
ABSTRACT
The stability of a formulated heparin was examined during its sterilization by autoclaving. A new method to follow loss in heparin binding to the serine protease inhibitor, antithrombin III, and the serine protease, thrombin, was developed using a surface plasmon resonance competitive binding assay. This loss in binding affinity correlated well with loss in antifactor IIa (thrombin) activity as well as antifactor Xa activity as measured using conventional amidolytic assays. Autoclaving also resulted in a modest breakdown of the heparin backbone as confirmed by a slight reduction in number-averaged and weight-averaged molecular weight and an increase in polydispersity. Although no clear changes were observed by nuclear magnetic resonance spectroscopy, disaccharide composition analysis using high-performance liquid chromatography-electrospray ionization-mass spectrometry suggested that loss of selected sulfo groups had taken place. It is this sulfo group loss that probably accounts for a decrease in the binding of autoclaved heparin to antithrombin III and thrombin as well as the observed decrease in its amidolytic activity.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Heparin / Sterilization / Hot Temperature / Anticoagulants Limits: Humans Language: En Journal: J Pharm Sci Year: 2011 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Heparin / Sterilization / Hot Temperature / Anticoagulants Limits: Humans Language: En Journal: J Pharm Sci Year: 2011 Document type: Article
...