Your browser doesn't support javascript.
loading
Variant of the anastigmatic telescope with three mirrors for back focal length.
Herrera, J; Vázquez, S; Luna, E; Salas, L; Nuñez, J; Sohn, E; Ruiz, E.
Affiliation
  • Herrera J; Universidad Nacional Autonoma de México, Instituto de Astronomía, Observatorio Astronomico Nacional. Apdo. Postal 877, Ensenada, B. C. 22800, Mexico. joel@astrosen.unam.mx
Appl Opt ; 50(13): 1905-14, 2011 May 01.
Article in En | MEDLINE | ID: mdl-21532673
ABSTRACT
In this paper, an optical design is presented for an anastigmatic telescope with back focal length corrected with exact ray tracing to eliminate spherical, coma, and astigmatism aberrations. The telescope is formed of three conical mirrors, two of them polished on the same substratum. The optical design is divided into three stages we began the design obtaining the Gaussian parameters in a first-order solution; posteriorly, were obtained analytically the three mirrors' asphericity in a third-order design. The final design stage consists of the implementation of the Fermat's principle, the Abbe sine condition, and the Coddington equations for the exact correction for the three aforementioned aberrations.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Appl Opt Year: 2011 Document type: Article Affiliation country: México