Rapid detection of coronary artery stenoses with real-time perfusion echocardiography during regadenoson stress.
Porter, Thomas R; Adolphson, Mary; High, Robin R; Smith, Lynette M; Olson, Joan; Erdkamp, Michelle; Xie, Feng; O'Leary, Edward; Wong, Benjamin F; Eifert-Rain, Susan; Hagen, Mary E; Abdelmoneim, Sahar S; Mulvagh, Sharon L.
Affiliation
  • Porter TR; University of Nebraska Medical Center, Omaha, NE 68198-8865, USA. trporter@unmc.edu
Circ Cardiovasc Imaging ; 4(6): 628-35, 2011 Nov.
Article in En | MEDLINE | ID: mdl-21946702
ABSTRACT

BACKGROUND:

Real-time myocardial contrast echocardiography permits the detection of myocardial perfusion abnormalities during stress echocardiography, which may improve the accuracy of the test in detecting coronary artery stenoses. We hypothesized that this technique could be used after a bolus injection of the selective A2A receptor agonist regadenoson to rapidly and safely detect coronary artery stenoses. METHODS AND

RESULTS:

In 100 patients referred for quantitative coronary angiography, real-time myocardial contrast echocardiography was performed during a continuous intravenous infusion of 3% Definity at baseline and at 2-minute intervals for up to 6 minutes after a regadenoson bolus injection (400 µg). Myocardial perfusion was assessed by examination of myocardial contrast replenishment after brief high mechanical index impulses. A perfusion defect was defined as a delay (>2 seconds) in myocardial contrast replenishment in 2 contiguous segments. Wall motion was also analyzed. The overall sensitivity/specificity/accuracy for myocardial perfusion analysis in detecting a >50% diameter stenosis was 80%/74%/78%, whereas for wall motion analysis it was 60%/72%/66% (P<0.001 for differences in sensitivity). Sensitivity for myocardial perfusion analysis was highest on images obtained during the first 2 minutes after regadenoson bolus (P<0.001 compared with wall motion), whereas wall motion sensitivity was highest at the 4-to-6-minute period after the bolus. No significant side effects occurred after regadenoson bolus injection.

CONCLUSIONS:

Regadenoson real-time myocardial contrast echocardiography appears to be a feasible, safe, and rapid noninvasive method for the detection of significant coronary artery stenoses.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Perfusion / Purines / Pyrazoles / Coronary Stenosis / Echocardiography, Stress Type of study: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Circ Cardiovasc Imaging Journal subject: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Year: 2011 Document type: Article Affiliation country: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Perfusion / Purines / Pyrazoles / Coronary Stenosis / Echocardiography, Stress Type of study: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Circ Cardiovasc Imaging Journal subject: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Year: 2011 Document type: Article Affiliation country: Estados Unidos