Your browser doesn't support javascript.
loading
Comparison of various methods for quantitative evaluation of myocardial infarct volume from magnetic resonance delayed enhancement data.
Baron, N; Kachenoura, N; Cluzel, P; Frouin, F; Herment, A; Grenier, P; Montalescot, G; Beygui, F.
Affiliation
  • Baron N; Cardiology Department, and INSERM U937, Pitie-Salpetriere Medical Center, Paris, France.
Int J Cardiol ; 167(3): 739-44, 2013 Aug 10.
Article in En | MEDLINE | ID: mdl-22459370
ABSTRACT

BACKGROUND:

Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) enables the estimation of myocardial infarct (MI) extent. Nevertheless, manual quantification is time consuming and subjective. We sought to assess MI volume with different quantitative methods in both acute (AMI) and chronic MI (CMI).

METHODS:

CMR was performed 50 ± 21 h after MI in 52 patients and was repeated 100 ± 21 days later in a subgroup of 34 patients. Then, necrosis volumes were quantified using 1) manual delineation, 2) automated fuzzy c-means method, and 3) +2 to 6 SD thresholding approaches. Results were compared against peak values of serum Troponin I (TnI), creatine kinase (CK) and left ventricular (LV) functional parameters LV ejection fraction (LVEF), indexed end-diastolic (EDVi), end-systolic volumes (ESVi) and the number of hypokinetic segments (NbHk).

RESULTS:

For CMI, quantitative evaluation of infarct size using manual, +2SD, +3 SD and fuzzy c-means provided equivalent results in terms of correlation coefficients for comparisons of MI volumes against LV function parameters (LVEF r>0.79, p<0.0001; ESVi r>0.82, p<0.0001, EDVi r>0.67, p<0.0001, NbHk r>0.54, p<0.0009). For AMI, +2SD and fuzzy c-means approaches provided higher correlations for comparisons of AMI volumes against biochemical markers (CK r>0.79, p<0.0001,TnI r>0.77, p<0.0001) and chronic LV function parameters (LVEF r>0.82, p<0.0001, NbHk r>0.59, p<0.0002).

CONCLUSIONS:

The fuzzy c-means and 2SD methods provided highest correlations with biochemical MI quantification as well as LV function parameters. The fuzzy c-means approach which does not require an arbitrary identification of the remote myocardium is fast and reproducible. It may be clinically useful in the evaluation of patients with MI.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Statistics as Topic / Magnetic Resonance Imaging, Cine / Myocardial Infarction Type of study: Evaluation_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Int J Cardiol Year: 2013 Document type: Article Affiliation country: Francia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Statistics as Topic / Magnetic Resonance Imaging, Cine / Myocardial Infarction Type of study: Evaluation_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Int J Cardiol Year: 2013 Document type: Article Affiliation country: Francia
...