Direct measurements of the ionization potential depression in a dense plasma.
Phys Rev Lett ; 109(6): 065002, 2012 Aug 10.
Article in En | MEDLINE | ID: mdl-23006275
ABSTRACT
We have used the Linac Coherent Light Source to generate solid-density aluminum plasmas at temperatures of up to 180 eV. By varying the photon energy of the x rays that both create and probe the plasma, and observing the K-α fluorescence, we can directly measure the position of the K edge of the highly charged ions within the system. The results are found to disagree with the predictions of the extensively used Stewart-Pyatt model, but are consistent with the earlier model of Ecker and Kröll, which predicts significantly greater depression of the ionization potential.
Search on Google
Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Phys Rev Lett Year: 2012 Document type: Article Affiliation country: Reino Unido