Your browser doesn't support javascript.
loading
Thoracic ultrasound confirmation of correct lung exclusion before one-lung ventilation during thoracic surgery.
Saporito, Andrea; Lo Piccolo, Antonio; Franceschini, Daniele; Tomasetti, Renato; Anselmi, Luciano.
Affiliation
  • Saporito A; Anesthesia Service, Bellinzona Regional Hospital, 6500 Bellinzona, Switzerland.
  • Lo Piccolo A; Anesthesia Service, Bellinzona Regional Hospital, 6500 Bellinzona, Switzerland.
  • Franceschini D; Anesthesia Service, Bellinzona Regional Hospital, 6500 Bellinzona, Switzerland.
  • Tomasetti R; Anesthesia Service, Bellinzona Regional Hospital, 6500 Bellinzona, Switzerland.
  • Anselmi L; Anesthesia Service, Bellinzona Regional Hospital, 6500 Bellinzona, Switzerland.
J Ultrasound ; 16(4): 195-9, 2013 Nov 09.
Article in En | MEDLINE | ID: mdl-24432174
INTRODUCTION: Fiberoptic bronchoscopy is the standard method for verifying the correct position of a double-lumen endotracheal tube (DLET) prior to one-lung ventilation. However, it must be performed by a specially trained anesthesiologist and is often resource consuming. The aim of this study was to compare this approach with thoracic ultrasound done by a nurse anesthetist in terms of sensitivity, specificity, and cost-effectiveness. METHODS: We conducted a prospective cross-over case-control study involving 51 adult patients consecutively undergoing thoracic surgery with one-lung ventilation. After orotracheal intubation with a DLET, correct exclusion of the lung being operated on exclusion was assessed first by a certified anesthesiologist using standard fiberoptic bronchoscopy and then by a trained nurse anesthetist using thoracic ultrasound. The nurse was blinded as to the findings of the anesthesiologist's examination. RESULTS: The two approaches proved to be equally sensitive and specific, but the ultrasound examination was more rapid. This factor, together with the fact that ultrasound was performed by a nurse instead of a physician, and the costs of materials and sterilization, had a significant economic impact amounting to a net saving of €37.20 ± 5.40 per case. CONCLUSIONS: Although fiberoptic bronchoscopy is still the gold standard for checking the position of a DLET, thoracic ultrasound is a specific, sensitive, cost-effective alternative, which can be used to rapidly verify the proper function of the tube based on the demonstration of correct lung exclusion.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Clinical_trials / Observational_studies Language: En Journal: J Ultrasound Year: 2013 Document type: Article Affiliation country: Suiza Country of publication: Italia

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Clinical_trials / Observational_studies Language: En Journal: J Ultrasound Year: 2013 Document type: Article Affiliation country: Suiza Country of publication: Italia