Your browser doesn't support javascript.
loading
Radiation safety issues in y-90 microsphere selective hepatic radioembolization therapy: possible radiation exposure from the patients.
Kim, Young-Chul; Kim, Yun-Hwan; Uhm, Soon-Ho; Seo, Yeon Seok; Park, Eun-Kyung; Oh, Sun-Young; Jeong, Eugene; Lee, Sinae; Choe, Jae-Gol.
Affiliation
  • Kim YC; Department of Nuclear Medicine, Korea University Anam Hospital, 126-1 Anam-dong 5-Ga, Seongbuk-Gu, Seoul 136-705 Republic of Korea.
  • Kim YH; Department of Diagnostic Radiology, Korea University Anam Hospital, 126-1 Anam-dong 5-Ga, Seongbuk-Gu, Seoul 136-705 Republic of Korea.
  • Uhm SH; Department of Internal Medicine (Gastroenterology), Korea University Anam Hospital, 126-1 Anam-dong 5-Ga, Seongbuk-Gu, Seoul 136-705 Republic of Korea.
  • Seo YS; Department of Internal Medicine (Gastroenterology), Korea University Anam Hospital, 126-1 Anam-dong 5-Ga, Seongbuk-Gu, Seoul 136-705 Republic of Korea.
  • Park EK; Department of Nuclear Medicine, Korea University Anam Hospital, 126-1 Anam-dong 5-Ga, Seongbuk-Gu, Seoul 136-705 Republic of Korea.
  • Oh SY; Department of Nuclear Medicine, Korea University Anam Hospital, 126-1 Anam-dong 5-Ga, Seongbuk-Gu, Seoul 136-705 Republic of Korea.
  • Jeong E; Department of Nuclear Medicine, Korea University Anam Hospital, 126-1 Anam-dong 5-Ga, Seongbuk-Gu, Seoul 136-705 Republic of Korea.
  • Lee S; Department of Nuclear Medicine, Korea University Anam Hospital, 126-1 Anam-dong 5-Ga, Seongbuk-Gu, Seoul 136-705 Republic of Korea.
  • Choe JG; Department of Nuclear Medicine, Korea University Anam Hospital, 126-1 Anam-dong 5-Ga, Seongbuk-Gu, Seoul 136-705 Republic of Korea.
Nucl Med Mol Imaging ; 44(4): 252-60, 2010 Dec.
Article in En | MEDLINE | ID: mdl-24899961
PURPOSE: The purpose of this study was to estimate the possible external radiation dose to other individuals from patients treated with Y-90 resin microspheres for unresectable hepatocellular carcinoma. METHODS: We designed the study prospectively to estimate the possible radiation dose to other individuals from patients who had been treated with Y-90 microspheres for unresectable hepatocellular carcinoma. We estimated the total effective dose equivalent (TEDE) using two methods: 'theoretical' TEDEs according to the administered activity and 'measured' TEDE based on the 'measured' ambient radiation exposure rate. We compared the results from each method to determine when we can release patients from confinement at the earliest time complying with the patient release criteria. RESULTS: A total of 20 administrations of Y-90 resin microspheres were done in 18 patients. The average administered activity was 1.2 ± 0.77 (0.28-2.97) GBq. The 'theoretical' TEDEs were in the range of 0.8-10 µSv. The 'measured' TEDEs were in the range of 2.31-185 µSv. The measured TEDEs tend to be higher than the theoretical TEDEs. The values of theoretical and measured TEDE were both far less than 1 mSv, the upper limit at which the licensee can release a patient without any written documents. CONCLUSION: The effective dose equivalent caused by the Y-90 microsphere administered patient is very low. It is safe in terms of radiation safety to the other individuals when Y-90 microsphere radioembolization therapy is done with dose less than 3 GBq. Because the measured TEDE tends to be higher than the theoretical TEDE, it is recommended to use 'measured' TEDE for determining patient release.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Nucl Med Mol Imaging Year: 2010 Document type: Article Country of publication: Alemania

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Nucl Med Mol Imaging Year: 2010 Document type: Article Country of publication: Alemania