Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.
Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F.
Affiliation
  • Han LR; Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, China.
  • Jin CX; Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, China.
  • Yan J; Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, China junycn@yeah.net.
  • Han SZ; Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, China.
  • He XB; Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, China.
  • Yang XF; Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, China.
Genet Mol Res ; 14(1): 2912-9, 2015 Mar 31.
Article in En | MEDLINE | ID: mdl-25867441
ABSTRACT
This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P < 0.05); however, there were no significant differences in radial-ulnar deviation, wrist range of motion, or wrist function score between groups (P > 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radius Fractures / External Fixators / Internal Fixators / Fractures, Comminuted / Fracture Fixation Type of study: Observational_studies / Prognostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Genet Mol Res Journal subject: BIOLOGIA MOLECULAR / GENETICA Year: 2015 Document type: Article Affiliation country: China Publication country: BR / BRASIL / BRASILE / BRAZIL / BRESIL

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radius Fractures / External Fixators / Internal Fixators / Fractures, Comminuted / Fracture Fixation Type of study: Observational_studies / Prognostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Genet Mol Res Journal subject: BIOLOGIA MOLECULAR / GENETICA Year: 2015 Document type: Article Affiliation country: China Publication country: BR / BRASIL / BRASILE / BRAZIL / BRESIL