The design of a correlation electron cyclotron emission system on J-TEXT.
Rev Sci Instrum
; 86(4): 043501, 2015 Apr.
Article
in En
| MEDLINE
| ID: mdl-25933856
ABSTRACT
To study the anomalous transport, a correlation electron cyclotron emission (CECE) was planned to be developed on J-TEXT for electron temperature fluctuation measurement. The spectral decorrelation method was employed for the CECE system. It was developed based on the previous 16-channel electron cyclotron emission system. They shared the optical transmission line and mixer. The CECE part consists of 4 channels. Two fixed frequency narrow band filters were used for two channels and two yttrium iron garnet (YIG) filters for the other two channels. To meet the measuring requirement, some tests have been taken for the YIG filters. The results show good performance of the filters. Gaussian optics is used to produce a good poloidal resolution. Wavenumbers resolved by the CECE diagnostic are k(θ) ≤ 1.5 rad/cm and k(r) ≤ 12 rad/cm. Some preliminary experiment results are also presented in this paper.