Your browser doesn't support javascript.
loading
Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods.
Fazlollahi, Amir; Bourgeat, Pierrick; Liang, Xiaoyun; Meriaudeau, Fabrice; Connelly, Alan; Salvado, Olivier; Calamante, Fernando.
Affiliation
  • Fazlollahi A; CSIRO Digital Productivity Flagship, The Australian e-Health Research Centre, Herston, QLD, Australia; Le2I, University of Burgundy, Le Creusot, France. Electronic address: fazlollahi@gmail.com.
  • Bourgeat P; CSIRO Digital Productivity Flagship, The Australian e-Health Research Centre, Herston, QLD, Australia.
  • Liang X; Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia.
  • Meriaudeau F; Le2I, University of Burgundy, Le Creusot, France.
  • Connelly A; Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia; Department of Medicine, Austin Health and Northern Health, University of Melbourne, Melbourne, Victoria, Australia.
  • Salvado O; CSIRO Digital Productivity Flagship, The Australian e-Health Research Centre, Herston, QLD, Australia.
  • Calamante F; Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia; Department of Medicine, Austin Health and Northern Health, University of Melbourne, Melbourne, Victoria, Australia.
Neuroimage ; 117: 191-201, 2015 Aug 15.
Article in En | MEDLINE | ID: mdl-26026814
ABSTRACT
Arterial spin labeling (ASL) is an emerging MRI technique for non-invasive measurement of cerebral blood flow (CBF). Compared to invasive perfusion imaging modalities, ASL suffers from low sensitivity due to poor signal-to-noise ratio (SNR), susceptibility to motion artifacts and low spatial resolution, all of which limit its reliability. In this work, the effects of various state of the art image processing techniques for addressing these ASL limitations are investigated. A processing pipeline consisting of motion correction, ASL motion correction imprecision removal, temporal and spatial filtering, partial volume effect correction, and CBF quantification was developed and assessed. To further improve the SNR for pseudo-continuous ASL (PCASL) by accounting for errors in tagging efficiency, the data from multiphase (MP) acquisitions were analyzed using a novel weighted-averaging scheme. The performances of each step in terms of SNR and reproducibility were evaluated using test-retest ASL data acquired from 12 young healthy subjects. The proposed processing pipeline was shown to improve the within-subject coefficient of variation and regional reproducibility by 17% and 16%, respectively, compared to CBF maps computed following motion correction but without the other processing steps. The CBF measurements of MP-PCASL compared to PCASL had on average 23% and 10% higher SNR and reproducibility, respectively.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Image Processing, Computer-Assisted / Brain / Magnetic Resonance Imaging Limits: Adult / Female / Humans / Male Language: En Journal: Neuroimage Journal subject: DIAGNOSTICO POR IMAGEM Year: 2015 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Image Processing, Computer-Assisted / Brain / Magnetic Resonance Imaging Limits: Adult / Female / Humans / Male Language: En Journal: Neuroimage Journal subject: DIAGNOSTICO POR IMAGEM Year: 2015 Document type: Article