Your browser doesn't support javascript.
loading
Assessing Anticoagulation Practice Patterns in Patients on Durable Mechanical Circulatory Support Devices: An International Survey.
Jennings, Douglas L; Horn, Edward T; Lyster, Haifa; Panos, Anthony L; Teuteberg, Jeffrey J; Lehmkuhl, Hans B; Perez, Alexandra; Shullo, Michael A.
Affiliation
  • Jennings DL; From the *Department of Pharmacy, New York Presbyterian Columbia University Medical Center, New York, New York; †Department of Pharmacy, Allegheny General Hospital, Pittsburgh, Pennsylvania; ‡Department of Cardiothoracic Transplantation and Mechanical Circulatory Support, Royal Brompton & Harefield NHS Foundation Trust, Middlesex, United Kingdom; §Department of Cardiothoracic Surgery, University of Miami, Miami, Florida; ¶Heart and Vascular Institute, University of Pittsburgh Medical Center,
ASAIO J ; 62(1): 28-32, 2016.
Article in En | MEDLINE | ID: mdl-26309097
Anticoagulation in mechanical circulatory support (MCS) patients dictated by local practice, and therefore uniform standards for management are lacking. To characterize the worldwide variance in anticoagulation and antiplatelet therapy in patients with MCS devices, a 42 item survey was created and distributed electronically in August 2014. The survey assessed the center-perceived thromboembolic risk (minimal, low, moderate, or high) and characterized the antiplatelet and anticoagulant strategies for the Thoratec HeartMate II (HMII) and HeartWare HVAD (HVAD). A total of 83/214 centers (39%) responded: North America (60/152), Europe (18/50), Australia (2/4), and Asia (3/8). Although the most common target international normalized ratio (INR) was 2-3 for both devices, significant variability exists. Anticoagulation intensity tended to be lower with the HMII, with more centers targeting INR values of less than 2.5. Aspirin monotherapy was the most common antiplatelet regimen; however, the HVAD patients were more likely to be on daily aspirin doses over 100 mg. In addition, parenteral bridging was more frequent with the HVAD device. While 43.8% of respondents indicated an increase in the perceived risk of HMII device thrombosis in 2014, intensification of anticoagulation (22%) or antiplatelet (11%) therapy was infrequent. Our findings verify the wide variety of anticoagulation practice patterns between MCS centers.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Thromboembolism / Platelet Aggregation Inhibitors / Heart-Assist Devices / Anticoagulants Type of study: Etiology_studies / Guideline / Prognostic_studies Limits: Humans Language: En Journal: ASAIO J Journal subject: TRANSPLANTE Year: 2016 Document type: Article Country of publication: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Thromboembolism / Platelet Aggregation Inhibitors / Heart-Assist Devices / Anticoagulants Type of study: Etiology_studies / Guideline / Prognostic_studies Limits: Humans Language: En Journal: ASAIO J Journal subject: TRANSPLANTE Year: 2016 Document type: Article Country of publication: Estados Unidos