Your browser doesn't support javascript.
loading
Structure design of and experimental research on a two-stage laval foam breaker for foam fluid recycling.
J Environ Biol ; 36 Spec No: 829-36, 2015 Jul.
Article in En | MEDLINE | ID: mdl-26387358
ABSTRACT
Environmental, economical and efficient antifoaming technology is the basis for achievement of foam drilling fluid recycling. The present study designed a novel two-stage laval mechanical foam breaker that primarily uses vacuum generated by Coanda effect and Laval principle to break foam. Numerical simulation results showed that the value and distribution of negative pressure of two-stage laval foam breaker were larger than that of the normal foam breaker. Experimental results showed that foam-breaking efficiency of two-stage laval foam breaker was higher than that of normal foam breaker, when gas-to-liquid ratio and liquid flow rate changed. The foam-breaking efficiency of normal foam breaker decreased rapidly with increasing foam stability, whereas the two-stage laval foam breaker remained unchanged. Foam base fluid would be recycled using two-stage laval foam breaker, which would reduce the foam drilling cost sharply and waste disposals that adverse by affect the environment.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Extraction and Processing Industry Type of study: Evaluation_studies Language: En Journal: J Environ Biol Year: 2015 Document type: Article
Search on Google