Your browser doesn't support javascript.
loading
Probing the Secondary Structure of Membrane Peptides Using (2)H-Labeled d(10)-Leucine via Site-Directed Spin-Labeling and Electron Spin Echo Envelope Modulation Spectroscopy.
Liu, Lishan; Sahu, Indra D; McCarrick, Robert M; Lorigan, Gary A.
Affiliation
  • Liu L; Department of Chemistry and Biochemistry, Miami University , Oxford, Ohio 45056, United States.
  • Sahu ID; Department of Chemistry and Biochemistry, Miami University , Oxford, Ohio 45056, United States.
  • McCarrick RM; Department of Chemistry and Biochemistry, Miami University , Oxford, Ohio 45056, United States.
  • Lorigan GA; Department of Chemistry and Biochemistry, Miami University , Oxford, Ohio 45056, United States.
J Phys Chem B ; 120(4): 633-40, 2016 Feb 04.
Article in En | MEDLINE | ID: mdl-26735335
Previously, we reported an electron spin echo envelope modulation (ESEEM) spectroscopic approach for probing the local secondary structure of membrane proteins and peptides utilizing (2)H isotopic labeling and site-directed spin-labeling (SDSL). In order to probe the secondary structure of a peptide sequence, an amino acid residue (i) side chain was (2)H-labeled, such as (2)H-labeled d10-Leucine, and a cysteine residue was strategically placed at a subsequent nearby position (denoted as i + 1 to i + 4) to which a nitroxide spin label was attached. In order to fully access and demonstrate the feasibility of this new ESEEM approach with (2)H-labeled d10-Leu, four Leu residues within the AChR M2δ peptide were fully mapped out using this ESEEM method. Unique (2)H-ESEEM patterns were observed with the (2)H-labeled d10-Leu for the AChR M2δ α-helical model peptide. For proteins and peptides with an α-helical secondary structure, deuterium modulation can be clearly observed for i ± 3 and i ± 4 samples, but not for i ± 2 samples. Also, a deuterium peak centered at the (2)H Larmor frequency of each i ± 4 sample always had a significantly higher intensity than the corresponding i + 3 sample. This unique feature can be potentially used to distinguish an α-helix from a π-helix or 310-helix. Moreover, (2)H modulation depth for ESEEM samples on Leu10 were significantly enhanced which was consistent with a kinked or curved structural model of the AChR M2δ peptide as suggested by previous MD simulations and NMR experiments.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Peptides / Spectrum Analysis / Spin Labels / Protein Structure, Secondary / Leucine Language: En Journal: J Phys Chem B Journal subject: QUIMICA Year: 2016 Document type: Article Affiliation country: Estados Unidos Country of publication: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Peptides / Spectrum Analysis / Spin Labels / Protein Structure, Secondary / Leucine Language: En Journal: J Phys Chem B Journal subject: QUIMICA Year: 2016 Document type: Article Affiliation country: Estados Unidos Country of publication: Estados Unidos