Your browser doesn't support javascript.
loading
Development of a control region-based mtDNA SNaPshot™ selection tool, integrated into a mini amplicon sequencing method.
Weiler, Natalie E C; de Vries, Gerda; Sijen, Titia.
Affiliation
  • Weiler NE; Netherlands Forensic Institute, Laan van Ypenburg 6, The Hague, 2497GB, The Netherlands.
  • de Vries G; Netherlands Forensic Institute, Laan van Ypenburg 6, The Hague, 2497GB, The Netherlands.
  • Sijen T; Netherlands Forensic Institute, Laan van Ypenburg 6, The Hague, 2497GB, The Netherlands. Electronic address: t.sijen@nfi.minvenj.nl.
Sci Justice ; 56(2): 96-103, 2016 Mar.
Article in En | MEDLINE | ID: mdl-26976467
ABSTRACT
Mitochondrial DNA (mtDNA) analysis is regularly applied to forensic DNA samples with limited amounts of nuclear DNA (nDNA), such as hair shafts and bones. Generally, this mtDNA analysis involves examination of the hypervariable control region by Sanger sequencing of amplified products. When samples are severely degraded, small-sized amplicons can be applied and an earlier described mini-mtDNA method by Eichmann et al. [1] that accommodates ten mini amplicons in two multiplexes is found to be a very robust approach. However, in cases with large numbers of samples, like when searching for hairs with an mtDNA profile deviant from that of the victim, the method is time (and cost) consuming. Previously, Chemale et al. [2] described a SNaPshot™-based screening tool for a Brazilian population that uses standard-size amplicons for HVS-I and HVS-II. Here, we describe a similar tool adapted to the full control region and compatible with mini-mtDNA amplicons. Eighteen single nucleotide polymorphisms (SNPs) were selected based on their relative frequencies in a European population. They showed a high discriminatory power in a Dutch population (97.2%). The 18 SNPs are assessed in two SNaPshot™ multiplexes that pair to the two mini-mtDNA amplification multiplexes. Degenerate bases are included to limit allele dropout due to SNPs at primer binding site positions. Three SNPs provide haplogroup information. Reliability testing showed no differences with Sanger sequencing results. Since mini-mtSNaPshot screening uses only a small portion of the same PCR products used for Sanger sequencing, no additional DNA extract is consumed, which is forensically advantageous.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: DNA, Mitochondrial / DNA Fingerprinting Limits: Female / Humans / Male Language: En Journal: Sci Justice Journal subject: JURISPRUDENCIA Year: 2016 Document type: Article Affiliation country: Países Bajos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: DNA, Mitochondrial / DNA Fingerprinting Limits: Female / Humans / Male Language: En Journal: Sci Justice Journal subject: JURISPRUDENCIA Year: 2016 Document type: Article Affiliation country: Países Bajos