Your browser doesn't support javascript.
loading
Development of a high-throughput multiplexed real time RT-PCR assay for detection of human pegivirus 1 and 2.
Frankel, Matthew; Forberg, Kenn; Coller, Kelly E; Berg, Michael G; Hackett, John; Cloherty, Gavin; Dawson, George J.
Affiliation
  • Frankel M; Abbott Laboratories, Abbott Park, IL, USA. Electronic address: matthew.frankel@abbott.com.
  • Forberg K; Abbott Laboratories, Abbott Park, IL, USA.
  • Coller KE; Abbott Laboratories, Abbott Park, IL, USA.
  • Berg MG; Abbott Laboratories, Abbott Park, IL, USA.
  • Hackett J; Abbott Laboratories, Abbott Park, IL, USA.
  • Cloherty G; Abbott Laboratories, Abbott Park, IL, USA.
  • Dawson GJ; Abbott Laboratories, Abbott Park, IL, USA.
J Virol Methods ; 241: 34-40, 2017 03.
Article in En | MEDLINE | ID: mdl-28012898
ABSTRACT
Human Pegivirus 2 (HPgV-2) was recently identified in the bloodstream of HCV-infected and multiply transfused individuals. Initial reports show HPgV-2 circulates at a low prevalence in HCV co-infected individuals, necessitating testing of large cohorts of samples to identify infected persons. The identification of additional HPgV-2 cases was facilitated by the development of a high throughput and reliable molecular reverse transcription polymerase chain reaction (RT-PCR) assay intended for use on the automated Abbott m2000 system with a capability of extracting and testing 96 samples at once. A dual target approach was taken to reduce the risk of a false-negative result, amplifying sequences within the 5' UTR and NS2/3 coding regions of HPgV-2. The assay was expanded to multiplex detection of the other human Pegivirus, HPgV-1 (formerly GBV-C), to allow simultaneous prevalence comparison. The limit of detection (LOD; 95% detection) for HPgV-2 was experimentally determined to be 126 copies/mL. Through use of the newly developed multiplex assay, 21 strains of HPgV-2 circulating in HCV past or present infections were identified, with all strains confirmed by next generation sequencing. The multiplexed assay has high specificity and showed no cross-reactivity of HPgV-2 with HPgV-1 or other Flaviviruses. This automated assay will be instrumental in future studies addressing HPgV-2 pathogenicity, prevalence, and sequence diversity.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: RNA, Viral / Reverse Transcriptase Polymerase Chain Reaction / GB virus C / Multiplex Polymerase Chain Reaction Type of study: Diagnostic_studies / Risk_factors_studies Limits: Humans Language: En Journal: J Virol Methods Year: 2017 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: RNA, Viral / Reverse Transcriptase Polymerase Chain Reaction / GB virus C / Multiplex Polymerase Chain Reaction Type of study: Diagnostic_studies / Risk_factors_studies Limits: Humans Language: En Journal: J Virol Methods Year: 2017 Document type: Article