Your browser doesn't support javascript.
loading
Vancomycin sorption on activated sludge Gram+ bacteria rather than on EPS; 3D Confocal Laser Scanning Microscopy time-lapse imaging.
Louvet, J N; Carrion, C; Stalder, T; Alrhmoun, M; Casellas, M; Potier, O; Pons, M N; Dagot, C.
Affiliation
  • Louvet JN; Université de Toulouse, INSA, LISBP, 135 Avenue de Rangueil, F-31077, Toulouse, France; Groupement de Recherche Eau Sol Environnement EA 4330, Site de l'ENSIL, Parc ESTER Technopôle, 16 rue Atlantis, 87068, Limoges Cedex, France.
  • Carrion C; Plateforme cytométrie imagerie et mathématiques, CHU Limoges-CNRS-Université de Limoges, 2 rue du Dr Marcland, 87025, Limoges Cedex, France.
  • Stalder T; Groupement de Recherche Eau Sol Environnement EA 4330, Site de l'ENSIL, Parc ESTER Technopôle, 16 rue Atlantis, 87068, Limoges Cedex, France; U12092 Inserm, Laboratoire debactériologie-virologie, Faculté de Médecine, 2 avenue du Docteur Marcland, 87000, Limoges Cedex, France.
  • Alrhmoun M; Groupement de Recherche Eau Sol Environnement EA 4330, Site de l'ENSIL, Parc ESTER Technopôle, 16 rue Atlantis, 87068, Limoges Cedex, France.
  • Casellas M; Groupement de Recherche Eau Sol Environnement EA 4330, Site de l'ENSIL, Parc ESTER Technopôle, 16 rue Atlantis, 87068, Limoges Cedex, France.
  • Potier O; Laboratoire Réactions et Génie des Procédés (UPR 3349 CNRS), Université de Lorraine, INPL, 1 rue Grandville, BP 20451, F-54001, Nancy Cedex, France.
  • Pons MN; Laboratoire Réactions et Génie des Procédés (UPR 3349 CNRS), Université de Lorraine, INPL, 1 rue Grandville, BP 20451, F-54001, Nancy Cedex, France.
  • Dagot C; Groupement de Recherche Eau Sol Environnement EA 4330, Site de l'ENSIL, Parc ESTER Technopôle, 16 rue Atlantis, 87068, Limoges Cedex, France. Electronic address: christophe.dagot@unilim.fr.
Water Res ; 124: 290-297, 2017 11 01.
Article in En | MEDLINE | ID: mdl-28772141
ABSTRACT
Antibiotics-bacteria interactions depend on antibiotic concentration at the scale of bacteria. This study investigates how vancomycin penetrates into activated sludge flocs and can be sorbed on the bacteria and extracellular polymeric substances (EPS). The 3D structure of flocs was imaged using EPS autofluorescence. The green fluorescent BODIPY® FL vancomycin was introduced in a microscopic chamber containing activated sludge and penetration of vancomycin into the flocs by diffusion was observed using time-lapse microscopy. The penetration depended on the floc structure, as long and large pores could go through the whole flocs making preferential path. The antibiotic concentration into the flocs was also found to depend on the sorption rate. BODIPY® FL vancomycin was found to bind preferentially into Gram+ bacteria than on EPS. The vancomycin adsorption constant on bacteria according to the linear adsorption model, Kdbacteria was estimated to be 5 times higher (SD 2.6) than the adsorption constant on EPS KdEPS. These results suggest that antibiotic removal by sorption into wastewater treatment plants could change according to the amount of bacteria in the sludge. Moreover, antibiotic concentration at the scale of bacteria could be significantly higher than the concentration in the bulk solution and this should be taken into account when studying antibiotic activity or biodegradation.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sewage / Water Pollutants, Chemical / Vancomycin / Gram-Positive Bacteria Language: En Journal: Water Res Year: 2017 Document type: Article Affiliation country: Francia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sewage / Water Pollutants, Chemical / Vancomycin / Gram-Positive Bacteria Language: En Journal: Water Res Year: 2017 Document type: Article Affiliation country: Francia