Your browser doesn't support javascript.
loading
The Mechanical Properties and Biometrical Effect of 3D Preformed Titanium Membrane for Guided Bone Regeneration on Alveolar Bone Defect.
Lee, So-Hyoun; Moon, Jong-Hoon; Jeong, Chang-Mo; Bae, Eun-Bin; Park, Chung-Eun; Jeon, Gye-Rok; Lee, Jin-Ju; Jeon, Young-Chan; Huh, Jung-Bo.
Affiliation
  • Lee SH; Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea.
  • Moon JH; Biomedical Engineering, School of Medicine, Pusan National University, Yangsan, Republic of Korea.
  • Jeong CM; Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea.
  • Bae EB; Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea.
  • Park CE; School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
  • Jeon GR; Biomedical Engineering, School of Medicine, Pusan National University, Yangsan, Republic of Korea.
  • Lee JJ; Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea.
  • Jeon YC; Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea.
  • Huh JB; Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea.
Biomed Res Int ; 2017: 7102123, 2017.
Article in En | MEDLINE | ID: mdl-29018818
The purpose of this study is to evaluate the effect of three-dimensional preformed titanium membrane (3D-PFTM) to enhance mechanical properties and ability of bone regeneration on the peri-implant bone defect. 3D-PFTMs by new mechanically compressive molding technology and manually shaped- (MS-) PFTMs by hand manipulation were applied in artificial peri-implant bone defect model for static compressive load test and cyclic fatigue load test. In 12 implants installed in the mandibular of three beagle dogs, six 3D-PFTMs, and six collagen membranes (CM) randomly were applied to 2.5 mm peri-implant buccal bone defect with particulate bone graft materials for guided bone regeneration (GBR). The 3D-PFTM group showed about 7.4 times higher mechanical stiffness and 5 times higher fatigue resistance than the MS-PFTM group. The levels of the new bone area (NBA, %), the bone-to-implant contact (BIC, %), distance from the new bone to the old bone (NB-OB, %), and distance from the osseointegration to the old bone (OI-OB, %) were significantly higher in the 3D-PFTM group than the CM group (p < .001). It was verified that the 3D-PFTM increased mechanical properties which were effective in supporting the space maintenance ability and stabilizing the particulate bone grafts, which led to highly efficient bone regeneration.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Titanium / Biocompatible Materials / Bone Regeneration / Alveolar Bone Loss / Alveolar Process Limits: Animals Language: En Journal: Biomed Res Int Year: 2017 Document type: Article Country of publication: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Titanium / Biocompatible Materials / Bone Regeneration / Alveolar Bone Loss / Alveolar Process Limits: Animals Language: En Journal: Biomed Res Int Year: 2017 Document type: Article Country of publication: Estados Unidos