Your browser doesn't support javascript.
loading
Development of a high current 60 keV neutral lithium beam injector for beam emission spectroscopy measurements on fusion experiments.
Anda, G; Dunai, D; Lampert, M; Krizsanóczi, T; Németh, J; Bató, S; Nam, Y U; Hu, G H; Zoletnik, S.
Affiliation
  • Anda G; Wigner RCP, EURATOM Association HAS, P.O. Box 49, Budapest H-1525, Hungary.
  • Dunai D; Wigner RCP, EURATOM Association HAS, P.O. Box 49, Budapest H-1525, Hungary.
  • Lampert M; Wigner RCP, EURATOM Association HAS, P.O. Box 49, Budapest H-1525, Hungary.
  • Krizsanóczi T; Wigner RCP, EURATOM Association HAS, P.O. Box 49, Budapest H-1525, Hungary.
  • Németh J; Wigner RCP, EURATOM Association HAS, P.O. Box 49, Budapest H-1525, Hungary.
  • Bató S; Wigner RCP, EURATOM Association HAS, P.O. Box 49, Budapest H-1525, Hungary.
  • Nam YU; National Fusion Research Institute, 52 Eoeun-dong, Yuseong-gu, Daejeon 305-333, South Korea.
  • Hu GH; Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei, China.
  • Zoletnik S; Wigner RCP, EURATOM Association HAS, P.O. Box 49, Budapest H-1525, Hungary.
Rev Sci Instrum ; 89(1): 013503, 2018 Jan.
Article in En | MEDLINE | ID: mdl-29390651
ABSTRACT
A 60 keV neutral lithium beam system was designed and built up for beam emission spectroscopy measurement of edge plasma on the KSTAR and EAST tokamaks. The electron density profile and its fluctuation can be measured using the accelerated lithium beam-based emission spectroscopy system. A thermionic ion source was developed with a SiC heater to emit around 4-5 mA ion current from a 14 mm diameter surface. The ion optic is following the 2 step design used on other devices with small modifications to reach about 2-3 cm beam diameter in the plasma at about 4 m from the ion source. A newly developed recirculating sodium vapour neutralizer neutralizes the accelerated ion beam at around 260-280 °C even during long (<20 s) discharges. A set of new beam diagnostic and manipulation techniques are applied to allow optimization, aiming, cleaning, and beam modulation. The maximum 60 keV beam energy with 4 mA ion current was successfully reached at KSTAR and at EAST. Combined with an efficient observation system, the Li-beam diagnostic enables the measurement of the density profile and fluctuations on the plasma turbulence time scale.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Rev Sci Instrum Year: 2018 Document type: Article Affiliation country: Hungria

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Rev Sci Instrum Year: 2018 Document type: Article Affiliation country: Hungria