Cryopreserved Human Allografts for the Reconstruction of Aortic and Peripheral Prosthetic Graft Infection.
Bossi, Matteo; Tozzi, Matteo; Franchin, Marco; Ferraro, Stefania; Rivolta, Nicola; Ferrario, Massimo; Guttadauro, Chiara; Castelli, Patrizio; Piffaretti, Gabriele.
Affiliation
  • Bossi M; Vascular Surgery, Department of Medicine and Surgery, Circolo University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy.
  • Tozzi M; Vascular Surgery, Department of Medicine and Surgery, Circolo University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy.
  • Franchin M; Vascular Surgery, Department of Medicine and Surgery, Circolo University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy.
  • Ferraro S; Vascular Surgery, Department of Medicine and Surgery, Circolo University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy.
  • Rivolta N; Vascular Surgery, Department of Medicine and Surgery, Circolo University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy.
  • Ferrario M; Vascular Surgery, Department of Medicine and Surgery, Circolo University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy.
  • Guttadauro C; Vascular Surgery, Department of Medicine and Surgery, Circolo University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy.
  • Castelli P; Vascular Surgery, Department of Medicine and Surgery, Circolo University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy.
  • Piffaretti G; Vascular Surgery, Department of Medicine and Surgery, Circolo University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy.
Ann Vasc Dis ; 10(4): 391-397, 2017 Dec 25.
Article in En | MEDLINE | ID: mdl-29515701
ABSTRACT

Background:

This study aimed to present cases with cryopreserved human allografts (CHAs) for vascular reconstruction in both aortic and peripheral infected prosthetic grafts. Materials and

Methods:

This is a single center, observational descriptive study with retrospective analysis. In all cases, the infected prosthetic graft material was completely removed. At discharge, patients were administered anticoagulants. Follow-up examinations included clinical visits, echo-color-Doppler ultrasounds, or computed tomography angiography within 30 days and at 3, 6, and 12 months after the treatment, and then twice per year.

Results:

We treated 21 patients (90% men, n=19) with the mean age of 71±12 years and mean interval between the initial operation and replacement with CHA of 30 months [range, 1-216; interquartile range (IQR), 2-36]. In-hospital mortality was 14% (n=3); no CHA-related complication led to death. Limb salvage was 100%. No patient was lost at the median follow-up of 14 months (range, 2-61; IQR, 6-39). No rupture, aneurysmal degeneration, or re-infection occurred. Estimated freedom from CHA-related adverse events (95% confidence interval, 43-63) was 95% at 3 years.

Conclusion:

In our experience, CHAs are a viable option for prosthetic graft infections and provide satisfactory clinical results and favorable stability because of a very low rate of CHA-related adverse events during follow-up.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Ann Vasc Dis Year: 2017 Document type: Article Affiliation country: Italia