Electrochemical Determination of TNT, DNT, RDX, and HMX with Gold Nanoparticles/Poly(Carbazole-Aniline) Film-Modified Glassy Carbon Sensor Electrodes Imprinted for Molecular Recognition of Nitroaromatics and Nitramines.
Saglam, Sener; Üzer, Aysem; Erçag, Erol; Apak, Resat.
Affiliation
  • Saglam S; Faculty of Engineering, Chemistry Department , Istanbul University , 34320 Istanbul , Turkey.
  • Üzer A; Faculty of Engineering, Chemistry Department , Istanbul University , 34320 Istanbul , Turkey.
  • Erçag E; Aytar Cad. , Fecri Ebcioglu Sok., No. 6/8, Levent , 34340 Istanbul , Turkey.
  • Apak R; Faculty of Engineering, Chemistry Department , Istanbul University , 34320 Istanbul , Turkey.
Anal Chem ; 90(12): 7364-7370, 2018 06 19.
Article in En | MEDLINE | ID: mdl-29786423
ABSTRACT
Since nitroaromatic- and nitramine-type energetic materials, mostly arising from military activities, are persistent pollutants in soil and groundwater, on-site sensing of these hazardous chemicals has gained importance. A novel electrochemical sensor was designed for detecting nitroaromatic- and nitramine-type energetic materials, relying on gold nanoparticles (Aunano), modified glassy carbon (GC) electrode coated with nitro-energetic memory-poly(carbazole-aniline) copolymer (Cz- co-ANI) film (e.g., TNT memory-GC/P(Cz- co-ANI)-Aunano modified electrode). Current was recorded against concentration to build the calibration curves that were found to be linear within the range of 100-1000 µg L-1 for 2,4,6-trinitrotoluene (TNT) and 2,4-dinitrotoluene (DNT) 50-1000 µg L-1 for 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). The corresponding limits of detection were 25 µg L-1 for TNT, 30 µg L-1 for DNT, and 10 µg L-1 for both RDX and HMX, using nitro-energetic memory-GC/P(Cz- co-ANI)-Aunano electrodes. These electrodes were used separately, and specific determinations were made in various mixtures of nitro-energetic materials. The developed method could be efficiently used in electroanalyzing nitroaromatics and nitramines in military explosives (i.e., comp B, octol, and comp A5). The sensor electrodes were specific for the tested nitro-energetic compounds and did not respond to paracetamol-caffeine-based analgesic drug, acetylsalicylic acid (aspirin), sweetener, and sugar that can be used as camouflage materials in passenger belongings. The developed method was statistically validated against the standard LC-MS reference method in contaminated clay soil samples containing TNT and RDX explosives.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Explosive Agents / Hydrocarbons, Aromatic / Aniline Compounds / Nitrobenzenes Language: En Journal: Anal Chem Year: 2018 Document type: Article Affiliation country: Turquía

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Explosive Agents / Hydrocarbons, Aromatic / Aniline Compounds / Nitrobenzenes Language: En Journal: Anal Chem Year: 2018 Document type: Article Affiliation country: Turquía