Your browser doesn't support javascript.
loading
Caution using data from triaxial accelerometers housed in player tracking units during running.
Edwards, Suzi; White, Samuel; Humphreys, Seaton; Robergs, Robert; O'Dwyer, Nicholas.
Affiliation
  • Edwards S; a School of Environmental and Life Sciences , University of Newcastle , Ourimbah , Australia.
  • White S; b Priority Research Centre for Physical Activity and Nutrition , University of Newcastle , Callaghan , Australia.
  • Humphreys S; c School of Exercise Science, Sport and Health , Charles Sturt University , Bathurst , Australia.
  • Robergs R; a School of Environmental and Life Sciences , University of Newcastle , Ourimbah , Australia.
  • O'Dwyer N; c School of Exercise Science, Sport and Health , Charles Sturt University , Bathurst , Australia.
J Sports Sci ; 37(7): 810-818, 2019 Apr.
Article in En | MEDLINE | ID: mdl-30306824
ABSTRACT
Usage of accelerometers within player tracking devices in sport to quantify load, vertical ground reaction force (vGRF) or energy expenditure is contrary to placement guidelines. This study aimed to determine whether trunk-mounted accelerometers were a valid and reliable method to estimate thoracic segment or centre of gravity (COG) acceleration or vGRF, and the whether the elasticised harness contributes to the overestimation of acceleration. Ten male amateur rugby players performed five linear running tasks per lower limb at three speeds, twice, each with a different player tracking unit. Three-dimensional data were recorded and triaxial accelerometers were attached lateral to the device on the harness and skin and both shanks. Accelerometers demonstrated poor reliability (ICC0.0-0.67), high variability (CV%14-33%) and change in mean (41-160%), and were not valid to estimate vertical acceleration of the COG and thoracic segment nor vGRF. Caution is advised when utilising trunk-mounted triaxial accelerometer data as it is not a valid or reliable means to estimate peak vertical acceleration for its thoracic location nor whole-body COG acceleration or vGRF during running. To improve player tracking instrument validity and reliability, a new attachment method and/or harness material(s), that reduce or eliminate extraneous acceleration during running, are urgently required.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Running / Accelerometry / Fitness Trackers Limits: Adult / Humans / Male Language: En Journal: J Sports Sci Year: 2019 Document type: Article Affiliation country: Australia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Running / Accelerometry / Fitness Trackers Limits: Adult / Humans / Male Language: En Journal: J Sports Sci Year: 2019 Document type: Article Affiliation country: Australia