Your browser doesn't support javascript.
loading
Investigation of scleral thermal injuries caused by ultrasonic pars plana phacoemulsification and aspiration using pig eyes.
Sato, Takaki; Yasuhara, Toru; Fukumoto, Masanori; Mimura, Masashi; Kobayashi, Takatoshi; Kida, Teruyo; Kojima, Shota; Oku, Hidehiro; Ikeda, Tsunehiko.
Affiliation
  • Sato T; Department of Ophthalmology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki-City, Osaka, 569-8686, Japan.
  • Yasuhara T; Yasuhara Eye Clinic, Takashima-City, Shiga, Japan.
  • Fukumoto M; Department of Ophthalmology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki-City, Osaka, 569-8686, Japan.
  • Mimura M; Department of Ophthalmology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki-City, Osaka, 569-8686, Japan.
  • Kobayashi T; Department of Ophthalmology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki-City, Osaka, 569-8686, Japan.
  • Kida T; Department of Ophthalmology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki-City, Osaka, 569-8686, Japan.
  • Kojima S; Department of Ophthalmology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki-City, Osaka, 569-8686, Japan.
  • Oku H; Department of Ophthalmology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki-City, Osaka, 569-8686, Japan.
  • Ikeda T; Department of Ophthalmology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki-City, Osaka, 569-8686, Japan. tikeda@poh.osaka-med.ac.jp.
Int Ophthalmol ; 39(9): 2015-2021, 2019 Sep.
Article in En | MEDLINE | ID: mdl-30353259
ABSTRACT

PURPOSE:

The purpose of this study was to investigate the thermal injuries caused by ultrasonic pars plana phacoemulsification and aspiration (PPPEA) using pig eyes.

METHOD:

Using a 20-gauge (G) vitrectomy system (Accurus®, Fragmatome; Alcon Laboratories) in both the 'open-tip' and 'closed-tip' techniques, PPPEA was performed in pig eyes and the subsequent thermal injuries generated around the scleral wound were measured by infrared thermal imaging (thermography). Post surgery, the state of the scleral wound was observed under a microscope, and a tissue slice containing the scleral wound was then prepared and observed under an optical microscope.

RESULTS:

Thermography measurements revealed a slight temperature rise around the scleral wound in the open-tip case, yet a marked temperature rise in the closed-tip case. The scleral wound incision produced by the open tip was linear, while that produced by the closed tip was expanded. Histological examination revealed mild degeneration of the sclera around the wound in the open-tip case, yet marked tissue degeneration by thermal injuries in the closed-tip case.

CONCLUSION:

Our findings showed that in PPPEA, the temperature of the tip of a 20G vitrectomy system rapidly increases due to the closed-tip technique, thus producing obvious thermal damage to the scleral wound. In order to prevent thermal injuries to the scleral wound during PPPEA, it is important to shorten the time of ultrasonic oscillation during surgery as much as possible while the tip is occluded with nuclear fragments.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sclera / Scleral Diseases / Eye Burns / Phacoemulsification / Paracentesis Type of study: Etiology_studies / Prognostic_studies Limits: Animals Language: En Journal: Int Ophthalmol Year: 2019 Document type: Article Affiliation country: Japón

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sclera / Scleral Diseases / Eye Burns / Phacoemulsification / Paracentesis Type of study: Etiology_studies / Prognostic_studies Limits: Animals Language: En Journal: Int Ophthalmol Year: 2019 Document type: Article Affiliation country: Japón