Diffusion tensor imaging of articular cartilage using a navigated radial imaging spin-echo diffusion (RAISED) sequence.
Eur Radiol
; 29(5): 2598-2607, 2019 May.
Article
in En
| MEDLINE
| ID: mdl-30382348
OBJECTIVE: To validate a radial imaging spin-echo diffusion tensor (RAISED) sequence for high-resolution diffusion tensor imaging (DTI) of articular cartilage at 3 T. METHODS: The RAISED sequence implementation is described, including the used non-linear motion correction algorithm. The robustness to eddy currents was tested on phantoms, and accuracy of measurement was assessed with measurements of temperature-dependent diffusion of free water. Motion correction was validated by comparing RAISED with single-shot diffusion-weighted echo-planar imaging (EPI) measures. DTI was acquired in asymptomatic subjects (n = 6) and subjects with doubtful (Kellgren-Lawrence [KL] grade 1, n = 9) and mild (KL = 2, n = 9) symptomatic knee osteoarthritis (OA). MD and FA values without correction, and after all corrections, were calculated. A test-retest evaluation of the DTI acquisition on three asymptomatic and three OA subjects was also performed. RESULTS: The root mean squared coefficient of variation of the global test-restest reproducibility was 3.54% for MD and 5.34% for FA. MD was significantly increased in both femoral condyles (7-9%) of KL 1 and in the medial (11-17%) and lateral (10-12%) compartments of KL 2 subjects. Averaged FA presented a trend of lower values with increasing KL grade, which was significant for the medial femoral condyle (-11%) of KL 1 and all three compartments in KL 2 subjects (-18 to -11%). Group differences in MD and FA were only significant after motion correction. CONCLUSION: The RAISED sequence with the proposed reconstruction framework provides reproducible assessment of DTI parameters in vivo at 3 T and potentially the early stages of the disease in large regions of interest. KEY POINTS: ⢠DTI of articular cartilage is feasible at 3T with a multi-shot RAISED sequence with non-linear motion correction. ⢠RAISED sequence allows estimation of the diffusion indices MD and FA with test-retest errors below 4% (MD) and 6% (FA). ⢠RAISED-based measurement of DTI of articular cartilage with non-linear motion correction holds potential to differentiate healthy from OA subjects.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Algorithms
/
Cartilage, Articular
/
Echo-Planar Imaging
/
Phantoms, Imaging
/
Osteoarthritis, Knee
/
Diffusion Tensor Imaging
/
Knee Joint
Limits:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Language:
En
Journal:
Eur Radiol
Journal subject:
RADIOLOGIA
Year:
2019
Document type:
Article
Affiliation country:
Estados Unidos
Country of publication:
Alemania