Your browser doesn't support javascript.
loading
Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring.
Jia, Ji; Xu, Chengtian; Pan, Shijia; Xia, Stephen; Wei, Peter; Noh, Hae Young; Zhang, Pei; Jiang, Xiaofan.
Affiliation
  • Jia J; Electrical Engineering Department, Columbia University, New York, NY 10027, USA. jj2860@columbia.edu.
  • Xu C; Electrical Engineering Department, Columbia University, New York, NY 10027, USA. cx2168@columbia.edu.
  • Pan S; Electrical and Computer Engineering Department, Carnegie Mellon University, Pittsburgh, PA 15213, USA. shijiapan@cmu.edu.
  • Xia S; Electrical Engineering Department, Columbia University, New York, NY 10027, USA. sx2194@columbia.edu.
  • Wei P; Electrical Engineering Department, Columbia University, New York, NY 10027, USA. pw2428@columbia.edu.
  • Noh HY; Civil and Environmental Engineering Department, Carnegie Mellon University, Pittsburgh, PA 15213, USA. noh@cmu.edu.
  • Zhang P; Electrical and Computer Engineering Department, Carnegie Mellon University, Pittsburgh, PA 15213, USA. peizhang@cmu.edu.
  • Jiang X; Electrical Engineering Department, Columbia University, New York, NY 10027, USA. jiang@ee.columbia.edu.
Sensors (Basel) ; 18(11)2018 Nov 05.
Article in En | MEDLINE | ID: mdl-30400608
ABSTRACT
Individual perspiration level indicates a person's physical status as well as their comfort level. Therefore, continuous perspiration level measurement enables people to monitor these conditions for applications including fitness assessment, athlete physical status monitoring, and patient/elderly care. Prior work on perspiration (sweat) sensing required the user either to be static or to wear the adhesive sensor directly on the skin, which limits users' mobility and comfort. In this paper, we present a novel conductive thread-based textile sensor that measures an individual's on-cloth sweat quantity. The sensor consists of three conductive threads. Each conductive thread is surrounded by a braided cotton cover. An additional braided cotton cover is placed outside the three conductive threads, holding them in a position that is stable for measurement. the sensor can be embedded at various locations on a person's clothing. When the person sweats, the cotton braids absorb the sweat and change the conductivity (resistance) between conductive threads. We used a voltage dividing circuit to measure this resistance as the sensor output (DC). We then conducted a sensor calibration to map this measured voltage to the quantity of electrolyte solution (with the same density as sweat) applied to the sensor. We used this sensor to measure individuals' perspiration quantity and infer their perceived perspiration levels. The system is able to limit the average prediction error to 0.4 levels when compared to five pre-defined perceived perspiration levels.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sweat / Textiles / Electric Conductivity / Monitoring, Physiologic Limits: Female / Humans / Male Language: En Journal: Sensors (Basel) Year: 2018 Document type: Article Affiliation country: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Sweat / Textiles / Electric Conductivity / Monitoring, Physiologic Limits: Female / Humans / Male Language: En Journal: Sensors (Basel) Year: 2018 Document type: Article Affiliation country: Estados Unidos