Your browser doesn't support javascript.
loading
Development and Validation of a LC⁻MS/MS-Based Assay for Quantification of Free and Total Omega 3 and 6 Fatty Acids from Human Plasma.
Serafim, Vlad; Tiugan, Diana-Andreea; Andreescu, Nicoleta; Mihailescu, Alexandra; Paul, Corina; Velea, Iulian; Puiu, Maria; Niculescu, Mihai Dinu.
Affiliation
  • Serafim V; Genetics Discipline, Centre of Genomic Medicine Timișoara, "Victor Babeș" University of Medicine and Pharmacy, No 2, Eftimie Murgu Square, Timișoara 300041, Romania. vladserafim@gmail.com.
  • Tiugan DA; Genetics Discipline, Centre of Genomic Medicine Timișoara, "Victor Babeș" University of Medicine and Pharmacy, No 2, Eftimie Murgu Square, Timișoara 300041, Romania. tiugandiana@gmail.com.
  • Andreescu N; "Louis Țurcanu" Clinical Emergency Hospital for Children, No 2, Iosif Nemoianu St., Timișoara 300011, Romania. tiugandiana@gmail.com.
  • Mihailescu A; Genetics Discipline, Centre of Genomic Medicine Timișoara, "Victor Babeș" University of Medicine and Pharmacy, No 2, Eftimie Murgu Square, Timișoara 300041, Romania. andreescu.nicoleta@umft.ro.
  • Paul C; "Louis Țurcanu" Clinical Emergency Hospital for Children, No 2, Iosif Nemoianu St., Timișoara 300011, Romania. andreescu.nicoleta@umft.ro.
  • Velea I; Genetics Discipline, Centre of Genomic Medicine Timișoara, "Victor Babeș" University of Medicine and Pharmacy, No 2, Eftimie Murgu Square, Timișoara 300041, Romania. alex.fifu@gmail.com.
  • Puiu M; Pediatric Department, "Victor Babeș" University of Medicine and Pharmacy, No 2, Eftimie Murgu Square, Timișoara 300041, Romania. corinapaul17@gmail.com.
  • Niculescu MD; Pediatric Department, "Victor Babeș" University of Medicine and Pharmacy, No 2, Eftimie Murgu Square, Timișoara 300041, Romania. ivelea56@yahoo.com.
Molecules ; 24(2)2019 Jan 20.
Article in En | MEDLINE | ID: mdl-30669503
ABSTRACT
Few high-performance liquid chromatography⁻tandem mass spectrometry (LC-MS/MS) methods have been developed for the full quantitation of fatty acids from human plasma without derivatization. Therefore, we propose a method that requires fewer sample preparation steps, which can be used for the quantitation of several polyunsaturated fatty acids in human plasma. The method offers rapid, accurate, sensitive, and simultaneous quantification of omega 3 (α-linolenic, eicosapentaenoic, and docosahexaenoic acids) and omega 6 fatty acids (arachidonic and linoleic acids) using high-performance LC-MS/MS. The selected fatty acids were analysed in lipid extracts from both free and total forms. Chromatographic separation was achieved using a reversed phase C18 column with isocratic flow using ammonium acetate for improving negative electrospray ionization (ESI) response. Mass detection was performed in multiple reaction monitoring (MRM) mode, and deuterated internal standards were used for each target compound. The limits of quantification were situated in the low nanomolar range, excepting linoleic acid, for which the limit was in the high nanomolar range. The method was validated according to the U.S. Department of Health and Human Services guidelines, and offers a fast, sensitive, and reliable quantification of selected omega 3 and 6 fatty acids in human plasma.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biological Assay / Fatty Acids, Omega-3 / Fatty Acids, Omega-6 Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2019 Document type: Article Affiliation country: Rumanía Publication country: CH / SUIZA / SUÍÇA / SWITZERLAND

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biological Assay / Fatty Acids, Omega-3 / Fatty Acids, Omega-6 Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2019 Document type: Article Affiliation country: Rumanía Publication country: CH / SUIZA / SUÍÇA / SWITZERLAND