Your browser doesn't support javascript.
loading
Coronary CT angiography radiation dose trends: A 10-year analysis to develop institutional diagnostic reference levels.
Lin, Zhu Xiao; Zhou, Chang Sheng; Schoepf, U Joseph; Eid, Marwen; Duguay, Taylor M; Greenberg, William T; Luo, Song; Quan, Wei; Zhou, Fan; Lu, Guang Ming; Zhang, Long Jiang.
Affiliation
  • Lin ZX; Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu 210002, China.
  • Zhou CS; Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu 210002, China.
  • Schoepf UJ; Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu 210002, China; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston,
  • Eid M; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston, SC 29425, United States.
  • Duguay TM; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston, SC 29425, United States.
  • Greenberg WT; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston, SC 29425, United States.
  • Luo S; Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu 210002, China.
  • Quan W; Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu 210002, China.
  • Zhou F; Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu 210002, China.
  • Lu GM; Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu 210002, China. Electronic address: cjr.luguangming@vip.163.com.
  • Zhang LJ; Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu 210002, China. Electronic address: kevinzhlj@163.com.
Eur J Radiol ; 113: 140-147, 2019 Apr.
Article in En | MEDLINE | ID: mdl-30927938
ABSTRACT

PURPOSE:

To develop institutional diagnostic reference levels (IDRL) for coronary CT angiography (CCTA) according to patient size by analyzing radiation dose changes over the past 10 years. MATERIALS AND

METHODS:

This IRB approved retrospective investigation analyzed radiation dose data from CCTA between 2007 and 2016 at our institution. Annual trends in radiation dose were described for each scanner type and scanning mode. Radiation levels were analyzed for normorhythmic patients, patients with prior coronary artery bypass grafting (CABG), arrhythmia, and according to patient size and tube voltage. Median, and quartile values for volume CT dose index (CTDIvol), dose-length product (DLP), and size-specific dose estimate (SSDE) were calculated. Wilcoxon rank-sum test and Kruskal Wallis test were performed to assess the significance of quantitative data.

RESULTS:

35,375 examinations from 33,317 patients (median age, 58 [50-66] years; male patients, 21,087 [58.7%]) were analyzed. CTDIvol, DLP, and SSDE significantly decreased by 9.0%, 30.8%, and 40.1% (all P < 0.05) for all examinations, respectively. All radiation dose metrics progressively decreased across scanning modes (especially retrospectively ECG-gated spiral and prospectively ECG-triggered high-pitch spiral acquisition mode), but did not significantly change across scanners in the last 6 years. CTDIvol and DLP increased with patient size when water-equivalent diameters were >19 cm for normorhythmic and CABG patients. In arrhythmic patients, CTDIvol increased progressively with water-equivalent diameters across all groups.

CONCLUSION:

CCTA radiation dose has progressively decreased in the past decade except in patients with prior CABG and arrhythmia. Size-specific IDRLs may optimize radiation utilization in these patients going forward.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Angiography / Computed Tomography Angiography Type of study: Diagnostic_studies / Observational_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Eur J Radiol Year: 2019 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Angiography / Computed Tomography Angiography Type of study: Diagnostic_studies / Observational_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Eur J Radiol Year: 2019 Document type: Article Affiliation country: China