Your browser doesn't support javascript.
loading
Model Image-Based Metal Artifact Reduction for Computed Tomography.
Luzhbin, Dmytro; Wu, Jay.
Affiliation
  • Luzhbin D; Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, No. 155, Sec. 2, Linong Street, Taipei, Taiwan, 11221, Republic of China.
  • Wu J; Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, No. 155, Sec. 2, Linong Street, Taipei, Taiwan, 11221, Republic of China. jaywu@ym.edu.tw.
J Digit Imaging ; 33(1): 71-82, 2020 02.
Article in En | MEDLINE | ID: mdl-31011955
ABSTRACT
Metal implants often produce severe artifacts in the reconstructed computed tomography (CT) images, causing information and image detail loss and making the CT images diagnostically unusable. In order to eliminate the metal artifacts and enhance the diagnostic value of the reconstructed CT images, a post-processing metal artifact reduction algorithm, based on a tissue-class model segmented by thresholding and k-means clustering with spatial information, is proposed. The image inpainting technique is incorporated into the algorithm to improve the segmentation accuracy for CT images severely corrupted by metal artifacts. A study of a water phantom and of two sets of clinical CT images was performed to test the algorithm performance. The proposed method effectively eliminates typical metal artifacts, restores the average CT numbers of different tissues to the proper levels, and preserves the edge and contrast information, thus allowing the accurate reconstruction of the tissue attenuation map. The quality of the artifact-corrected CT images allows them to be subsequently used in other clinical applications, such as three-dimensional rendering, dose estimation for radiotherapy, attenuation correction for PET and SPECT, etc. The algorithm does not rely on the use of the raw sinogram and so is not limited by the proprietary format restrictions.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tomography, X-Ray Computed / Artifacts Limits: Humans Language: En Journal: J Digit Imaging Journal subject: DIAGNOSTICO POR IMAGEM / INFORMATICA MEDICA / RADIOLOGIA Year: 2020 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tomography, X-Ray Computed / Artifacts Limits: Humans Language: En Journal: J Digit Imaging Journal subject: DIAGNOSTICO POR IMAGEM / INFORMATICA MEDICA / RADIOLOGIA Year: 2020 Document type: Article Affiliation country: China