Your browser doesn't support javascript.
loading
Label-Free Electrochemical Immunosensor Based on a Functionalized Ionic Liquid and Helical Carbon Nanotubes for the Determination of Cardiac Troponin I.
Shen, Qihui; Liu, Man; Lü, Yang; Zhang, Dawei; Cheng, Zhenyu; Liu, Yan; Gao, Huajing; Jin, Zhaohui.
Affiliation
  • Shen Q; Department of Chemistry and Pharmaceutical Engineering and Department of Petrochemical Technology, Jilin Institute of Chemical Technology, Jilin 132022, P. R. China.
  • Liu M; State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, College of Chemistry, Jilin University, Changchun 130012, P. R. China.
  • Lü Y; Department of Chemistry and Pharmaceutical Engineering and Department of Petrochemical Technology, Jilin Institute of Chemical Technology, Jilin 132022, P. R. China.
  • Zhang D; Department of Chemistry and Pharmaceutical Engineering and Department of Petrochemical Technology, Jilin Institute of Chemical Technology, Jilin 132022, P. R. China.
  • Cheng Z; Department of Chemistry and Pharmaceutical Engineering and Department of Petrochemical Technology, Jilin Institute of Chemical Technology, Jilin 132022, P. R. China.
  • Liu Y; Department of Chemistry and Pharmaceutical Engineering and Department of Petrochemical Technology, Jilin Institute of Chemical Technology, Jilin 132022, P. R. China.
  • Gao H; Department of Chemistry and Pharmaceutical Engineering and Department of Petrochemical Technology, Jilin Institute of Chemical Technology, Jilin 132022, P. R. China.
  • Jin Z; Department of Chemistry and Pharmaceutical Engineering and Department of Petrochemical Technology, Jilin Institute of Chemical Technology, Jilin 132022, P. R. China.
ACS Omega ; 4(7): 11888-11892, 2019 Jul 31.
Article in En | MEDLINE | ID: mdl-31460299
ABSTRACT
A label-free electrochemical immunosensor for cardiac troponin I was prepared by using a helical carbon nanotube-supported aldehyde-functionalized ionic liquid. Because of the good conductivity of ionic liquid and helical carbon nanotubes, high sensitivity of the immunosensor was obtained. Functionalized ionic liquid provided binding sites for antibody, which simplified the process of sensor construction. Cardiac troponin I was detected by this immunosensor with a linear range of 0.05-30 ng/mL and a detection limit of 0.03 ng/mL. The electrochemical immunosensor had satisfactory reproducibility, high sensitivity, and acceptable specificity.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ACS Omega Year: 2019 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ACS Omega Year: 2019 Document type: Article