Your browser doesn't support javascript.
loading
Effect of Low-Intensity vs Standard-Intensity Warfarin Prophylaxis on Venous Thromboembolism or Death Among Patients Undergoing Hip or Knee Arthroplasty: A Randomized Clinical Trial.
Gage, Brian F; Bass, Anne R; Lin, Hannah; Woller, Scott C; Stevens, Scott M; Al-Hammadi, Noor; Anderson, Jeffrey L; Li, Juan; Rodriguez, Tomás; Miller, J Philip; McMillin, Gwendolyn A; Pendleton, Robert C; Jaffer, Amir K; King, Cristi R; Whipple, Brandi; Porche-Sorbet, Rhonda; Napoli, Lynnae; Merritt, Kerri; Thompson, Anna M; Hyun, Gina; Hollomon, Wesley; Barrack, Robert L; Nunley, Ryan M; Moskowitz, Gerard; Dávila-Román, Victor; Eby, Charles S.
Affiliation
  • Gage BF; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Bass AR; Department of Medicine, Hospital for Special Surgery, New York, New York.
  • Lin H; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Woller SC; Department of Medical Education, University of Massachusetts, Worcester.
  • Stevens SM; Department of Medicine, Intermountain Medical Center, Salt Lake City, Utah.
  • Al-Hammadi N; Department of Medicine, University of Utah, Salt Lake City.
  • Anderson JL; Department of Medicine, Intermountain Medical Center, Salt Lake City, Utah.
  • Li J; Department of Medicine, University of Utah, Salt Lake City.
  • Rodriguez T; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Miller JP; Department of Medicine, University of Utah, Salt Lake City.
  • McMillin GA; Department of Cardiology, Intermountain Medical Center, Salt Lake City, Utah.
  • Pendleton RC; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Jaffer AK; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • King CR; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Whipple B; Department of Pathology, University of Utah, Salt Lake City.
  • Porche-Sorbet R; Department of Medicine, University of Utah, Salt Lake City.
  • Napoli L; Department of Medicine, New York Presbyterian Queens Hospital, New York.
  • Merritt K; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Thompson AM; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Hyun G; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Hollomon W; Department of Medicine, University of Utah, Salt Lake City.
  • Barrack RL; Department of Medicine, Hospital for Special Surgery, New York, New York.
  • Nunley RM; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Moskowitz G; Department of Medical Education, University of Central Florida College of Medicine, Orlando.
  • Dávila-Román V; Department of Medicine, Washington University in St Louis, St Louis, Missouri.
  • Eby CS; Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland.
JAMA ; 322(9): 834-842, 2019 09 03.
Article in En | MEDLINE | ID: mdl-31479138
Importance: The optimal international normalized ratio (INR) to prevent venous thromboembolism (VTE) in warfarin-treated patients with recent arthroplasty is unknown. Objective: To determine the safety and efficacy of a target INR of 1.8 vs 2.5 for VTE prophylaxis after orthopedic surgery. Design, Setting, and Participants: The randomized Genetic Informatics Trial (GIFT) of Warfarin to Prevent Deep Vein Thrombosis enrolled 1650 patients aged 65 years or older initiating warfarin for elective hip or knee arthroplasty at 6 US medical centers. Enrollment began in April 2011 and follow-up concluded in October 2016. Interventions: In a 2 × 2 factorial design, participants were randomized to a target INR of 1.8 (n = 823) or 2.5 (n = 827) and to either genotype-guided or clinically guided warfarin dosing. For the first 11 days of therapy, open-label warfarin dosing was guided by a web application. Main Outcomes and Measures: The primary outcome was the composite of VTE (within 60 days) or death (within 30 days). Participants underwent screening duplex ultrasound postoperatively. The hypothesis was that an INR target of 1.8 would be noninferior to an INR target of 2.5, using a noninferiority margin of 3% for the absolute risk of VTE. Secondary end points were bleeding and INR values of 4 or more. Results: Among 1650 patients who were randomized (mean age, 72.1 years; 1049 women [63.6%]; 1502 white [91.0%]), 1597 (96.8%) received at least 1 dose of warfarin and were included in the primary analysis. The rate of the primary composite outcome of VTE or death was 5.1% (41 of 804) in the low-intensity-warfarin group (INR target, 1.8) vs 3.8% (30 of 793) in the standard-treatment-warfarin group (INR target, 2.5), for a difference of 1.3% (1-sided 95% CI, -∞ to 3.05%, P = .06 for noninferiority). Major bleeding occurred in 0.4% of patients in the low-intensity group and 0.9% of patients in the standard-intensity group, for a difference of -0.5% (95% CI, -1.6% to 0.4%). The INR values of 4 or more occurred in 4.5% of patients in the low-intensity group and 12.2% of the standard-intensity group, for a difference of -7.8% (95% CI, -10.5% to -5.1%). Conclusions and Relevance: Among older patients undergoing hip or knee arthroplasty and receiving warfarin prophylaxis, an international normalized ratio goal of 1.8 compared with 2.5 did not meet the criterion for noninferiority for risk of the composite outcome of VTE or death. However, the trial may have been underpowered to meet this criterion and further research may be warranted. Trial Registration: ClinicalTrials.gov Identifier: NCT01006733.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Warfarin / International Normalized Ratio / Arthroplasty, Replacement, Hip / Arthroplasty, Replacement, Knee / Venous Thromboembolism / Anticoagulants Type of study: Clinical_trials / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male Language: En Journal: JAMA Year: 2019 Document type: Article Country of publication: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Warfarin / International Normalized Ratio / Arthroplasty, Replacement, Hip / Arthroplasty, Replacement, Knee / Venous Thromboembolism / Anticoagulants Type of study: Clinical_trials / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male Language: En Journal: JAMA Year: 2019 Document type: Article Country of publication: Estados Unidos