Your browser doesn't support javascript.
loading
Efficacy and Safety of High-Intensity Focused Ultrasound for Noninvasive Abdominal Subcutaneous Fat Reduction.
Hong, Ji Yeon; Ko, Eun Jung; Choi, Sun Young; Kwon, Tae-Rin; Kim, Jong Hwan; Kim, Soo Yeon; Kim, Beom Joon.
Affiliation
  • Hong JY; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, Korea.
  • Ko EJ; Department of Dermatology, National Police Hospital, Seoul, Korea.
  • Choi SY; Department of Dermatology, Seoul Paik Hospital, Inje University College of Medicine, Seoul, Korea.
  • Kwon TR; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, Korea.
  • Kim JH; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, Korea.
  • Kim SY; Clinical development team, Classys Inc., Seoul, Korea.
  • Kim BJ; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, Korea.
Dermatol Surg ; 46(2): 213-219, 2020 02.
Article in En | MEDLINE | ID: mdl-31490305
ABSTRACT

BACKGROUND:

Demand for noninvasive body contouring has increased.

OBJECTIVE:

We evaluated the efficacy and safety of a thermal high-intensity focused ultrasound (HIFU) device for abdominal body shaping. PATIENTS AND

METHODS:

Adults with a body mass index ≤30 kg/m and an abdominal subcutaneous fat tissue thickness ≥2.5 cm were enrolled for HIFU treatment at energy levels of 150 J/cm (first session) and 135 J/cm (second session). The primary end point was a change from baseline waist circumference at post-treatment Week 8. Secondary efficacy end points were changes in body weight, waist/hip ratio, and fat thickness assessed by ultrasound, caliper, and a fat CT scan. The Global Aesthetic Improvement Scale was evaluated by both investigators and subjects.

RESULTS:

The primary assessment achieved statistical significance, showing a reduction of 3.43 cm in mean waist circumference. The treatment effect was cumulative, with a steady decrease in waist circumference and fat thickness. The mean pain scores immediately after treatment were 4.45 ± 2.74 on a scale of 1 to 10 with 10 being the most painful, which decreased to 1.10 ± 1.33 after 1 week.

CONCLUSION:

High-intensity focused ultrasound is an effective and safe treatment modality for reducing waist circumference in nonobese individuals with focal fat accumulation.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Subcutaneous Fat, Abdominal / Obesity, Abdominal / High-Intensity Focused Ultrasound Ablation / Pain, Procedural / Body Contouring Type of study: Etiology_studies Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Dermatol Surg Journal subject: DERMATOLOGIA Year: 2020 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Subcutaneous Fat, Abdominal / Obesity, Abdominal / High-Intensity Focused Ultrasound Ablation / Pain, Procedural / Body Contouring Type of study: Etiology_studies Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Dermatol Surg Journal subject: DERMATOLOGIA Year: 2020 Document type: Article