Your browser doesn't support javascript.
loading
Investigation of (micro-)meteoritic materials at the new hard X-ray imaging PUMA beamline for heritage sciences.
Tack, Pieter; Bazi, Benjamin; Vekemans, Bart; Okbinoglu, Tulin; Van Maldeghem, Flore; Goderis, Steven; Schöder, Sebastian; Vincze, Laszlo.
Affiliation
  • Tack P; Chemistry, Ghent University, Krijgslaan 281 S12, 9000 Ghent, Belgium.
  • Bazi B; Chemistry, Ghent University, Krijgslaan 281 S12, 9000 Ghent, Belgium.
  • Vekemans B; Chemistry, Ghent University, Krijgslaan 281 S12, 9000 Ghent, Belgium.
  • Okbinoglu T; PUMA beamline, Synchrotron SOLEIL, Saint-Aubin BP48, F-91192 Gif-sur-Yvette, France.
  • Van Maldeghem F; Analytical-, Environmental- and Geo-chemistry, Vrije Universiteit Brussel, Pleinlaan 2, 1000 Brussels, Belgium.
  • Goderis S; Analytical-, Environmental- and Geo-chemistry, Vrije Universiteit Brussel, Pleinlaan 2, 1000 Brussels, Belgium.
  • Schöder S; PUMA beamline, Synchrotron SOLEIL, Saint-Aubin BP48, F-91192 Gif-sur-Yvette, France.
  • Vincze L; Chemistry, Ghent University, Krijgslaan 281 S12, 9000 Ghent, Belgium.
J Synchrotron Radiat ; 26(Pt 6): 2033-2039, 2019 Nov 01.
Article in En | MEDLINE | ID: mdl-31721748
ABSTRACT
At the French synchrotron facility SOLEIL, a new X-ray imaging facility PUMA (Photons Utilisés pour les Matériaux Anciens) has been made available to scientific communities studying materials from cultural heritage. This new instrument aims to achieve 2D and 3D imaging with microscopic resolution, applying different analytical techniques including X-ray fluorescence spectroscopy (XRF), X-ray absorption spectroscopy (XAS), X-ray diffraction and phase-contrast imaging. In order to discover its capabilities a detailed analytical characterization of this beamline as an analytical and imaging tool is deemed necessary. In this work, (confocal) XRF and XAS analyses are demonstrated using the Seymchan pallasite meteorite and an Antarctic unmelted micrometeorite as case studies. The obtained spatial resolution (2 µm × 3 µm) and sensitivity (detection limits <10 p.p.m. for 1 s acquisition at 18 keV) show that PUMA is a competitive state-of-the-art beamline, providing several high-profile and high-in-demand analytical methods while maintaining applicability towards a wide range of heritage-oriented sciences.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2019 Document type: Article Affiliation country: Bélgica

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Synchrotron Radiat Journal subject: RADIOLOGIA Year: 2019 Document type: Article Affiliation country: Bélgica